Relationships between Size-specific Dose Estimate and Signal to Noise Ratio under Chest CT Examinations with Tube Current Modulation

Author(s): Tian Qin, Jing Wang, Mengting Wang, Ye Gu, Zongyu Xie and Baohui Liang*

Volume 20, 2024

Published on: 20 February, 2024

Article ID: e15734056267251 Pages: 10

DOI: 10.2174/0115734056267251231121064259

Price: $65

Abstract

Purpose: Exploring the relationship between the signal-to-noise ratio (SNR) of organs and size-specific dose estimate (SSDE) in tube current modulation (TCM) chest CT examination.

Methods: Forty patients who received TCM chest CT scanning were retrospectively collected and divided into four groups according to the tube voltage and sexes. We chose to set up the region of interest (ROI) at the tracheal bifurcation and its upper and lower parts in slice images of the heart, aorta, lungs, paracranial muscles, and female breast, and the SNR of each organ was calculated. We also calculated the corresponding axial volume CT dose index (CTDIvolz) and axial size-specific dose estimate (SSDEz).

Results: The correlation analysis showed that the correlation between the SNR of the slice images of most organs and SSDEz was more significant than 0.8, and that between the SNR and CTDIvol was more significant than 0.7. The simple linear regression analysis results showed that when the sex is the same, the SNR of the same organ at 100kVp was higher than 120kVp, except for the lung. In multiple regression analysis, the result indicated that the determination coefficients of the SNR and SSDEz of the four groups were 0.934, 0.971, 0.905, and 0.709, respectively.

Conclusion: In chest CT examinations with TCM, the correlation between the SNR of each organ in slice images and SSDEz was better than that of CTDIvolz. And when the SSDEz was the same, the SNR at 100 kVp was better than that at 120 kVp.

[1]
Damilakis J, Dosimetry CT. CT Dosimetry. Invest Radiol 2021; 56(1): 62-8.
[http://dx.doi.org/10.1097/RLI.0000000000000727] [PMID: 32932380]
[2]
Shope TB, Gagne RM, Johnson GC. A method for describing the doses delivered by transmission x-ray computed tomography. Med Phys 1981; 8(4): 488-95.
[http://dx.doi.org/10.1118/1.594995] [PMID: 7322067]
[3]
Steiniger B, Klippel C, Teichgräber U, Reichenbach JR, Fiebich M. Can the size-specific dose estimate be derived from the body mass index? a feasibility study. Radiat Prot Dosimetry 2022; 198(6): 325-33.
[http://dx.doi.org/10.1093/rpd/ncac038] [PMID: 35443046]
[4]
Strauss K, Boone J, Cody D, McCollough C, McNitt-Gray M, Toth T. Size Specific Dose Estimates in Pediatric and Adult Body CT Examinations, AAPM Task Group 2014; 2011
[5]
Boone JM, Strauss K, Cody DD. Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations. (AAPM). College Park (MD): American Association of Physicists in Medicine 2011.
[6]
Yuan Z. Comparison of different SSDE methods in evaluating the radiation dose in chest and abdomen CT scan. Chi J Radi and Prot 2016; 36(11): 852-6.
[7]
McCollough CH, Bruesewitz MR, Kofler JM Jr. CT dose reduction and dose management tools: Overview of available options. Radiographics 2006; 26(2): 503-12.
[http://dx.doi.org/10.1148/rg.262055138] [PMID: 16549613]
[8]
Kwon JK, Chang IH, Moon YT, Lee JB, Park HJ, Park SB. Usefulness of low-dose nonenhanced computed tomography with iterative reconstruction for evaluation of urolithiasis: diagnostic performance and agreement between the urologist and the radiologist. Urology 2015; 85(3): 531-8.
[http://dx.doi.org/10.1016/j.urology.2014.11.021] [PMID: 25733262]
[9]
Larson DB. Optimizing CT radiation dose based on patient size and image quality: The size-specific dose estimate method. Pediatr Radiol 2014; 44(S3) (Suppl. 3): 501-5.
[http://dx.doi.org/10.1007/s00247-014-3077-y] [PMID: 25304711]
[10]
Khoramian D, Sistani S, Firouzjah RA. Assessment and comparison of radiation dose and image quality in multi-detector CT scanners in non-contrast head and neck examinations. Pol J Radiol 2019; 84: 61-7.
[http://dx.doi.org/10.5114/pjr.2019.82743] [PMID: 31019596]
[11]
Spampinato MV, Stalcup S, Matheus MG, et al. Radiation dose and image quality in pediatric head ct. Radiat Prot Dosimetry 2018; 182(3): 310-6.
[http://dx.doi.org/10.1093/rpd/ncy066] [PMID: 30590841]
[12]
Rajaraman V, Ponnusamy M, Halanaik D. Size specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT/CT. Asia Ocean J Nucl Med Biol 2020; 8(1): 58-63.
[PMID: 32064284]
[13]
Barreto I, Verma N, Quails N, Olguin C, Correa N, Mohammed TL. Patient size matters: Effect of tube current modulation on size-specific dose estimates (SSDE) and image quality in low-dose lung cancer screening CT. J Appl Clin Med Phys 2020; 21(4): 87-94.
[http://dx.doi.org/10.1002/acm2.12857] [PMID: 32250062]
[14]
Yurt A, Özsoykal İ, Obuz F. Effects of the use of automatic tube current modulation on patient dose and image quality in computed tomography. Mol Imaging Radionucl Ther 2019; 28(3): 96-103.
[http://dx.doi.org/10.4274/mirt.galenos.2019.83723] [PMID: 31507141]
[15]
Larson DB, Malarik RJ, Hall SM, Podberesky DJ. System for verifiable CT radiation dose optimization based on image quality. part II. process control system. Radiology 2013; 269(1): 177-85.
[http://dx.doi.org/10.1148/radiol.13122321] [PMID: 23784877]
[16]
Braun FM, Johnson TRC, Sommer WH, Thierfelder KM, Meinel FG. Chest CT using spectral filtration: Radiation dose, image quality, and spectrum of clinical utility. Eur Radiol 2015; 25(6): 1598-606.
[http://dx.doi.org/10.1007/s00330-014-3559-1] [PMID: 25515204]
[17]
Shu Hongmin. Effects of different ASIR levels and thickness of reconstructive layer on the quality of low-dose CT images of urinary calculi. Acta Universitatis Medicinalis Anhui 2019; 54(09): 1489-92.
[18]
Kawashima H, Ichikawa K, Hanaoka S, Matsubara K, Takata T. Relationship between size-specific dose estimates and image quality in computed tomography depending on patient size. J Appl Clin Med Phys 2018; 19(4): 246-51.
[http://dx.doi.org/10.1002/acm2.12340] [PMID: 29729075]
[19]
Funama Y, Sugaya Y, Miyazaki O, Utsunomiya D, Yamashita Y, Awai K. Automatic exposure control at MDCT based on the contrast-to-noise ratio: Theoretical background and phantom study. Phys Med 2013; 29(1): 39-47.
[http://dx.doi.org/10.1016/j.ejmp.2011.11.004] [PMID: 22182517]
[20]
MacDougall RD, Kleinman PL, Callahan MJ. Size-based protocol optimization using automatic tube current modulation and automatic kV selection in computed tomography. J Appl Clin Med Phys 2016; 17(1): 328-41.
[http://dx.doi.org/10.1120/jacmp.v17i1.5756] [PMID: 26894344]
[21]
McCollough CH, Leng S, Yu L, Cody DD, Boone JM, McNitt-Gray MF. CT dose index and patient dose: They are not the same thing. Radiology 2011; 259(2): 311-6.
[http://dx.doi.org/10.1148/radiol.11101800] [PMID: 21502387]
[22]
Burton C, Szczykutowicz T. Evaluation of AAPM Reports 204 and 220: Estimation of effective diameter, water-equivalent diameter, and ellipticity ratios for chest, abdomen, pelvis, and head CT scans. J Appl Clin Med Phys 2017; 19.
[PMID: 29178549]
[23]
Li X, Samei E, Segars WP, et al. Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients. Med Phys 2011; 38(1): 408-19.
[http://dx.doi.org/10.1118/1.3515864] [PMID: 21361209]
[24]
Franck C, Vandevoorde C, Goethals I, et al. The role of size-specific dose estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations. Eur Radiol 2016; 26(8): 2646-55.
[http://dx.doi.org/10.1007/s00330-015-4091-7] [PMID: 26670320]
[25]
Ledenius K, Gustavsson M, Johansson S, Stålhammar F, Wiklund L-M, Thilander-KLANG A. Effect of tube current on diagnostic image quality in paediatric cerebral multidetector CT images. Br J Radiol 2009; 82(976): 313-20.
[http://dx.doi.org/10.1259/bjr/24404354] [PMID: 19188246]
[26]
Tang K, Wang L, Li R, Lin J, Zheng X, Cao G. Effect of low tube voltage on image quality, radiation dose, and low-contrast detectability at abdominal multidetector CT: phantom study. J Biomed Biotechnol 2012; 2012: 1-6.
[http://dx.doi.org/10.1155/2012/130169] [PMID: 22619490]
[27]
Hagspiel KD, Flors L, Housseini AM, et al. Pulmonary blood volume imaging with dual-energy computed tomography: Spectrum of findings. Clin Radiol 2012; 67(1): 69-77.
[http://dx.doi.org/10.1016/j.crad.2010.12.021] [PMID: 22070940]
[28]
Dalah EZ, Obaideen A, Anam S, Alzimami K, Jambi LK, Bradley DA. Gender based lung cancer risks for symptomatic coronary artery disease patients undergone cardiac CT. PLoS One 2022; 17(4): e0265609.
[http://dx.doi.org/10.1371/journal.pone.0265609] [PMID: 35404962]

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy