Abstract
The measurement result of the performance of the decoupling capacitors which were used on several redesigned MB of the commercialized workstation is presented.
Keywords: Decoupling performance, workstatiion mother board (MB), meander trace, radiated electric field (EF) strength common mode (CM) current, magnetic field (MF) strength, three terminal capacitors, ferrite beads, PDN layer, immunity test, signal trace (ST) layer, ground plane (GP) layer, power plane (PP) layer, power trace (PT) layer, spectra, I/O signal cables, current probe, magnetic near-field, semi aneechoic chamber.