Background N-nitrosodimethylamine (NDMA) are a sort of genotoxic impurities (GTIs) having strong carcinogenic effects and obvious hepatotoxicity. To monitor the NDMA content of metformin hydrochloride sustained-release tablets and enteric capsules in China from 2018 to 2022, a GC-MS/MS method was established and validated.
Materials and Methods: The chromatographic column was Agilent VF-WAXms capillary column (30 m×0.25 mm, 0.25 μm). The GC-MS/MS method was equipped with multiple reaction monitoring (MRM) modes. To assess the quantity of NDMA, the molecular ion at mass-tocharge (m/z) of 74-44 was monitored under the 6 V collision energy, and to assess the quality of NDMA monitoring, the molecular ions at m/z 74-42 were determined. A total of 143 batches of metformin hydrochloride-finished products from 35 enterprises were determined by this method.
Results: The linear range of the method was 0.25 ~ 50.00 ng/mL, r = 0.9998, S/N > 10, and the limit of detection and quantitation were 0.06 ng/mL and 0.21 ng/mL, respectively. The average recovery was 98.62%, and the RSD was 4.31%. All batches of enteric capsules met the requirements; 38.21% of the 123 batches sustained-release tablets still exceeded the acceptable daily intake.
Conclusion: The presented method is sensitive, accurate, precise, and available for both enteric capsules and sustained-release tablets of metformin hydrochloride, which can provide a reference for their quality control. The over-limit phenomenon of NDMA in metformin hydrochloride products poses new challenges and requirements for both the State Drug Administration and enterprises.
Graphical Abstract
[http://dx.doi.org/10.1016/j.yrtph.2020.104749] [PMID: 32777431]
[http://dx.doi.org/10.1002/em.20406] [PMID: 18618583]
[http://dx.doi.org/10.1016/j.addr.2006.10.007] [PMID: 17188779]
[http://dx.doi.org/10.1634/theoncologist.2020-0142] [PMID: 32267983]
[http://dx.doi.org/10.1016/0015-6264(71)90306-3] [PMID: 4997817]
[http://dx.doi.org/10.3109/03602539709002243] [PMID: 9421685]
[http://dx.doi.org/10.1016/j.xphs.2023.01.026] [PMID: 36736776]
[http://dx.doi.org/10.1038/s41598-022-26691-0] [PMID: 36575247]
[http://dx.doi.org/10.1021/acs.jmedchem.0c02120] [PMID: 33706513]
[http://dx.doi.org/10.1016/j.jpba.2020.113460] [PMID: 32663759]
[http://dx.doi.org/10.3390/jcm10010153] [PMID: 33466237]
[http://dx.doi.org/10.1111/jpi.12369] [PMID: 27696512]
[http://dx.doi.org/10.1016/j.jpba.2019.05.022] [PMID: 31122801]
[http://dx.doi.org/10.1016/j.jpba.2018.11.010] [PMID: 30458387]
[http://dx.doi.org/10.1002/rcm.9414] [PMID: 36239213]
[http://dx.doi.org/10.1016/j.ejps.2021.106026] [PMID: 34597792]