Generic placeholder image

Current Medical Imaging

Editor-in-Chief

ISSN (Print): 1573-4056
ISSN (Online): 1875-6603

Research Article

Semi-automatic Framework for Voxel Human Deformation Modeling

Author(s): Yangchun Gao, Xu Xu, Congsheng Li, Jie Liu and Tongning Wu*

Volume 20, 2024

Published on: 02 August, 2023

Article ID: e130623217916 Pages: 9

DOI: 10.2174/1573405620666230613103727

Price: $65

Abstract

Background: With the advancement of computer and medical imaging technologies, a number of high-resolution, voxel-based, full-body human anatomical models have been developed for medical education, industrial design, and physics simulation studies. However, these models are limited in many applications because they are often only in an upstanding posture.

Objective: To quickly develop multi-pose human models for different applications. A semi-automatic framework for voxel deformation is proposed in the study.

Methods: This paper describes a framework for human pose deformation based on three-dimensional (3D) medical images. The voxel model is first converted into a surface model using a surface reconstruction algorithm. Second, a deformation skeleton based on human bones is defined, and the surface model is bound to the skeleton. The bone Glow algorithm is used to assign weights to the surface vertices. Then, the model is deformed to the target posture by using the Smoothed Rotation Enhanced As-Rigid-As-Possible (SR-ARAP) algorithm. Finally, the volume-filling algorithm is applied to refill the tissues into the deformed surface model.

Results: The proposed framework is used to deform two standing human models, and the sitting and running models are developed. The results show that the framework can successfully develop the target pose. When compared to the results of the As-Rigid-As-Possible algorithm, SR-ARAP preserves local tissues better.

Conclusion: The study proposes a frame for voxel human model deformation and improves the local tissue integrity during deformation.

[1]
Dimbylow PJ, Mann SM. SAR calculations in an anatomically realistic model of the head for mobile communication transceivers at 900 MHz and 1.8 GHz. Phys Med Biol 1994; 39(10): 1537-53.
[http://dx.doi.org/10.1088/0031-9155/39/10/003] [PMID: 15551530]
[2]
Gandhi OP, Lazzi G, Furse CM. Electromagnetic absorption in the human head and neck for mobile telephones at 835 and 1900 MHz. IEEE Trans Microw Theory Tech 1996; 44(10): 1884-97.
[http://dx.doi.org/10.1109/22.539947]
[3]
Wang J, Fujiwara O. FDTD analysis of dosimetry in human head model for a helical antenna portable telephone. IEICE Trans Commun 2000; 83(3): 549-54.
[4]
Nagaoka T, Watanabe S, Sakurai K, et al. Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic-field dosimetry. Phys Med Biol 2004; 49(1): 1-15.
[http://dx.doi.org/10.1088/0031-9155/49/1/001] [PMID: 14971769]
[5]
Wu T, Tan L, Shao Q, et al. Chinese adult anatomical models and the application in evaluation of RF exposures. Phys Med Biol 2011; 56(7): 2075-89.
[http://dx.doi.org/10.1088/0031-9155/56/7/011] [PMID: 21386138]
[6]
Christ A, Kainz W, Hahn EG, et al. The virtual family—development of surface-based anatomical models of two adults and two children for dosimetric simulations. Phys Med Biol 2010; 55(2): N23-38.
[http://dx.doi.org/10.1088/0031-9155/55/2/N01] [PMID: 20019402]
[7]
Gosselin MC, Neufeld E, Moser H, et al. Development of a new generation of high-resolution anatomical models for medical device evaluation: The Virtual Population 3.0. Phys Med Biol 2014; 59(18): 5287-303.
[http://dx.doi.org/10.1088/0031-9155/59/18/5287] [PMID: 25144615]
[8]
Artamonova AV. Virtual family: Forms and functions. Mediterr J Soc Sci 2015; 6
[http://dx.doi.org/10.5901/mjss.2015.v6n6s4p572]
[9]
Liu W, Wang H, Zhang P, et al. Statistical evaluation of radiofrequency exposure during magnetic resonant imaging: Application of whole-body individual human model and body motion in the coil. Int J Environ Res Public Health 2019; 16(6): 1069.
[http://dx.doi.org/10.3390/ijerph16061069] [PMID: 30934647]
[10]
Li C, Wu T. Dosimetry of infant exposure to power-frequency magnetic fields: Variation of 99th percentile induced electric field value by posture and skin-to-skin contact. Bioelectromagnetics 2015; 36(3): 204-18.
[http://dx.doi.org/10.1002/bem.21899] [PMID: 25708724]
[11]
Li C, Chen Z, Yang L, et al. Generation of infant anatomical models for evaluating electromagnetic field exposures. Bioelectromagnetics 2015; 36(1): 10-26.
[http://dx.doi.org/10.1002/bem.21868] [PMID: 25328088]
[12]
Zhang C, Li C, Yang L, et al. Assessment of twin fetal exposure to environmental magnetic and electromagnetic fields. Bioelectromagnetics 2022; 43(3): 160-73.
[http://dx.doi.org/10.1002/bem.22397] [PMID: 35233784]
[13]
Heutinck P, Knoops P, Florez NR, et al. Statistical shape modelling for the analysis of head shape variations. J Craniomaxillofac Surg 2021; 49(6): 449-55.
[http://dx.doi.org/10.1016/j.jcms.2021.02.020] [PMID: 33712336]
[14]
Jiang Y, Wang H, Sun X, Li C, Wu T. Evaluation of Chinese populational exposure to environmental electromagnetic field based on stochastic dosimetry and parametric human modelling. Environ Sci Pollut Res Int 2023; 30(14): 40445-60.
[http://dx.doi.org/10.1007/s11356-023-25153-y] [PMID: 36609755]
[15]
Findlay RP, Dimbylow PJ. Effects of posture on FDTD calculations of specific absorption rate in a voxel model of the human body. Phys Med Biol 2005; 50(16): 3825-35.
[http://dx.doi.org/10.1088/0031-9155/50/16/011] [PMID: 16077229]
[16]
Findlay RP, Dimbylow PJ. FDTD calculations of specific energy absorption rate in a seated voxel model of the human body from 10 MHz to 3 GHz. Phys Med Biol 2006; 51(9): 2339-52.
[http://dx.doi.org/10.1088/0031-9155/51/9/016] [PMID: 16625046]
[17]
Dawson TW, Caputa K, Stuchly MA. Numerical evaluation of 60 Hz magnetic induction in the human body in complex occupational environments. Phys Med Biol 1999; 44(4): 1025-40.
[http://dx.doi.org/10.1088/0031-9155/44/4/015] [PMID: 10232812]
[18]
Dawson TW, Caputa K, Stuchly MA. Magnetic field exposures for UK live-line workers. Phys Med Biol 2002; 47(7): 995-1012.
[http://dx.doi.org/10.1088/0031-9155/47/7/301] [PMID: 11996065]
[19]
Nagaoka T, Watanabe S. Voxel-based variable posture models of human anatomy. Proc IEEE 2009; 97(12): 2015-25.
[http://dx.doi.org/10.1109/JPROC.2009.2025662]
[20]
Faraj N, Thiery JM, Boubekeur T. VoxMorph: 3-scale freeform deformation of large voxel grids. Comput Graph 2012; 36(5): 562-8.
[http://dx.doi.org/10.1016/j.cag.2012.03.020]
[21]
Zhu X, Ding M, Zhang X. Free form deformation and symmetry constraint‐based multi‐modal brain image registration using generative adversarial nets. CAAI Trans Intell Technol 2023; cit2.12159.
[http://dx.doi.org/10.1049/cit2.12159]
[22]
Jung H, Oh M, Lee S. Learning free-form deformation for 3D face reconstruction from in-the-wild images. 2021 IEEE International Conference on Systems, Man, and Cybernetics (SMC). 2737-42.
[http://dx.doi.org/10.1109/SMC52423.2021.9659124]
[23]
Wareham R, Lasenby J. Bone glow: An improved method for the assignment of weights for mesh deformation. Articulated Motion and Deformable Objects. 2008; pp. 63-71.
[http://dx.doi.org/10.1007/978-3-540-70517-8_7]
[24]
Lorensen WE, Cline HE. Marching cubes: A high resolution 3D surface construction algorithm. Comput Graph 1987; 21(4): 163-9.
[http://dx.doi.org/10.1145/37402.37422]
[25]
Wu XJ, Wang MY, Han B. An automatic hole-filling algorithm for polygon meshes. Comput Aided Des Appl 2008; 5(6): 889-99.
[http://dx.doi.org/10.3722/cadaps.2008.889-899]
[26]
Sorkine-Hornung O, Alexa M. As-Rigid-As-Possible Surface Modeling. Eurographics Symposium on Geometry Processing.
[27]
Desbrun M, Meyer M, Schröder P, Barr AH. Implicit fairing of irregular meshes using diffusion and curvature flow. International Conference on Computer Graphics and Interactive Techniques.
[http://dx.doi.org/10.1145/311535.311576]
[28]
Baran I, Popović J. Automatic rigging and animation of 3D characters. ACM SIGGRAPH 2007; 26(3): 72–es.
[http://dx.doi.org/10.1145/1276377.1276467]
[29]
van der Vorst HA. Bi-CGSTAB: A fast and smoothly converging variant of Bi-CG for the solution of nonsymmetric linear systems. SIAM J Sci Statist Comput 1992; 13(2): 631-44.
[http://dx.doi.org/10.1137/0913035]
[30]
Liu A, Joe B. Relationship between tetrahedron shape measures. BIT 1994; 34(2): 268-87.
[http://dx.doi.org/10.1007/BF01955874]

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy