Abstract
A simple, reliable and selective differential pulse (DP) and square wave (SW) voltammetric methods at glassy carbon (GC) and boron-doped diamond (BDD) electrodes of lornoxicam in pharmaceutical dosage form and in spiked human serum samples have been developed and evaluated. The possible oxidation mechanism was discussed. The voltammetric study of the model compounds allowed elucidating the possible oxidation mechanism of lornoxicam. The dependence of the peak current and peak potentials on pH, concentration, nature of the buffer, and scan rate were investigated. The oxidation of lornoxicam gave a single and irreversible peak at both electrodes. The process was found diffusion controlled. For glassy carbon electrode, the linearity of the calibration curve was obtained in the range of 4×10-7 M to 2×10-5 M for DPV method and 4×10-7 M to 4×10-5 M for SWV method in 0,1 M sulphuric acid solutions. Using boron-doped diamond electrode, the plot of the calibration curve was linear between 6×10-7 M and 1×10-4 M for both voltammetric methods in pH 2 BR buffer. The repeatability, reproducibility, precision and accuracy of the proposed methods were investigated.
Keywords: Lornoxicam, voltammetry, boron-doped diamond electrode, glassy carbon electrode, pharmaceutical dosage form, serum
Combinatorial Chemistry & High Throughput Screening
Title: Applications of Carbon Based Electrodes for Voltammetric Determination of Lornoxicam in Pharmaceutical Dosage Form and Human Serum
Volume: 13 Issue: 7
Author(s): Burcin Bozal and Bengi Uslu
Affiliation:
Keywords: Lornoxicam, voltammetry, boron-doped diamond electrode, glassy carbon electrode, pharmaceutical dosage form, serum
Abstract: A simple, reliable and selective differential pulse (DP) and square wave (SW) voltammetric methods at glassy carbon (GC) and boron-doped diamond (BDD) electrodes of lornoxicam in pharmaceutical dosage form and in spiked human serum samples have been developed and evaluated. The possible oxidation mechanism was discussed. The voltammetric study of the model compounds allowed elucidating the possible oxidation mechanism of lornoxicam. The dependence of the peak current and peak potentials on pH, concentration, nature of the buffer, and scan rate were investigated. The oxidation of lornoxicam gave a single and irreversible peak at both electrodes. The process was found diffusion controlled. For glassy carbon electrode, the linearity of the calibration curve was obtained in the range of 4×10-7 M to 2×10-5 M for DPV method and 4×10-7 M to 4×10-5 M for SWV method in 0,1 M sulphuric acid solutions. Using boron-doped diamond electrode, the plot of the calibration curve was linear between 6×10-7 M and 1×10-4 M for both voltammetric methods in pH 2 BR buffer. The repeatability, reproducibility, precision and accuracy of the proposed methods were investigated.
Export Options
About this article
Cite this article as:
Bozal Burcin and Uslu Bengi, Applications of Carbon Based Electrodes for Voltammetric Determination of Lornoxicam in Pharmaceutical Dosage Form and Human Serum, Combinatorial Chemistry & High Throughput Screening 2010; 13 (7) . https://dx.doi.org/10.2174/1386207311004070599
DOI https://dx.doi.org/10.2174/1386207311004070599 |
Print ISSN 1386-2073 |
Publisher Name Bentham Science Publisher |
Online ISSN 1875-5402 |
- Author Guidelines
- Graphical Abstracts
- Fabricating and Stating False Information
- Research Misconduct
- Post Publication Discussions and Corrections
- Publishing Ethics and Rectitude
- Increase Visibility of Your Article
- Archiving Policies
- Peer Review Workflow
- Order Your Article Before Print
- Promote Your Article
- Manuscript Transfer Facility
- Editorial Policies
- Allegations from Whistleblowers
Related Articles
-
Vascular Endothelial Growth Factor Receptor 1, a Therapeutic Target in Cancer, Inflammation and Other Disorders
Current Medicinal Chemistry Guanylate Cyclase C: A Current Hot Target, from Physiology to Pathology
Current Medicinal Chemistry Therapeutic Targets in Inflammatory Disease
Current Medicinal Chemistry Long Term Prognosis in IgG4-Related Systemic Disease (ISD)
Current Immunology Reviews (Discontinued) In Vivo Inhibition of the Estrogen Sulfatase Enzyme and Growth of DMBA-Induced Mammary Tumors by Melatonin
Current Cancer Drug Targets Computational Analysis of Specific IgE Epitopes Responsible for Allergy to Fish
Current Immunology Reviews (Discontinued) Astrocytic Target Mechanisms in Epilepsy
Current Medicinal Chemistry Addressing MIST (Metabolites in Safety Testing): Bioanalytical Approaches to Address Metabolite Exposures in Humans and Animals
Current Drug Metabolism Nitric Oxide: Target for Therapeutic Strategies in Alzheimers Disease
Current Pharmaceutical Design Cyclophilin function in Cancer; lessons from virus replication
Current Molecular Pharmacology Ethanol and Inflammation
Anti-Inflammatory & Anti-Allergy Agents in Medicinal Chemistry Nuclear Receptor SHP as a Potential Therapeutic Target for Liver Cancer
Current Cancer Therapy Reviews A Current Understanding of Ocular Immune Privilege
Current Immunology Reviews (Discontinued) Defensins: Key Molecules in Ocular Surface Protection
Current Immunology Reviews (Discontinued) Proteasome Structure, Function, and Lessons Learned from Beta-Lactone Inhibitors
Current Topics in Medicinal Chemistry The Dual Role of Tumor Necrosis Factor (TNF) in Cancer Biology
Current Medicinal Chemistry Viral MicroRNAs: Interfering the Interferon Signaling
Current Pharmaceutical Design Chemical Space of FLT3 Inhibitors as Potential Anti-AML Drugs
Recent Patents on Anti-Cancer Drug Discovery Antioxidative Properties of Flavonoids
Current Organic Chemistry Endogenous Cardioprotective Agents: Role in Pre and Postconditioning
Current Drug Targets