Generic placeholder image

Current Cardiology Reviews

Editor-in-Chief

ISSN (Print): 1573-403X
ISSN (Online): 1875-6557

Review Article

Aortic Regurgitation as a Complication of Electrophysiologic Ablation Techniques: A Narrative Review

Author(s): Esraa Shehata, Mohamed Samy Abdel-Samie, Ahmad Elkoumy, Ahmed Yehia, Osama Soliman and Mohammad Abdelghani*

Volume 17, Issue 6, 2021

Published on: 08 April, 2021

Article ID: e051121192738 Pages: 7

DOI: 10.2174/1573403X17666210408093447

Price: $65

Abstract

Background: Radiofrequency catheter ablation is a well-established treatment for several cardiac arrhythmias. Arrhythmias originating from the left side of the heart including ventricular and supraventricular tachycardia and ectopy can be successfully ablated through either transseptal or retrograde aortic approach. Although these techniques have a generally low rate of complications, aortic valve injury is a potential complication of ablation at the left cardiac side that warrants more investigation.

Objective: The purpose of this review is to evaluate the incidence of iatrogenic aortic valve regurgitation and explore the potential mechanisms and risk factors that might contribute to aortic valve injury during radiofrequency ablation. Additionally, the course and progression of aortic regurgitation in the reported cases will be described.

Methods: Authors searched PubMed for articles using the keywords “ablation” AND “aortic insufficiency” OR “aortic valve injury” OR “aortic regurgitation”. Case reports and series as well as retrospective and prospective studies were included, and relevant review articles and editorial comments were used as a supplementary source of data. A total of 19 references were used and a detailed description of patient characteristics, procedural techniques, and incidence, predictors, and fate of aortic regurgitation were reported by 11 clinical studies.

Results: There is a small risk of significant iatrogenic aortic regurgitation after radiofrequency ablation of left-sided cardiac arrhythmias, especially techniques performed via a retrograde aortic approach.

Conclusion: Although the risk is not confined to procedures applying direct energy to the aortic cusp region, a more aggressive ablation applied in the vicinity of the valvular complex seems to be associated with a higher risk. Routine post-procedural surveillance should be adopted to detect de novo aortic valve injury following radiofrequency ablation techniques.

Keywords: Aortic regurgitation, aortic valve injury, radiofrequency ablation, arrhythmia, aortic insufficiency, tachycardias.

Graphical Abstract


Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy