Generic placeholder image

Recent Advances in Electrical & Electronic Engineering

Editor-in-Chief

ISSN (Print): 2352-0965
ISSN (Online): 2352-0973

Research Article

PMSM DTC Drive System Fed by a Fault-Tolerant Inverter

Author(s): Moez Abassi*, Oussama Saadaoui, Amor Khlaief, Abdelkader Chaari and Mohamed Boussak

Volume 12, Issue 1, 2019

Page: [61 - 67] Pages: 7

DOI: 10.2174/2352096511666180501125421

Price: $65

Abstract

Background: In this paper, experimentation fault-tolerant control for permanent magnet synchronous motor drive system using the direct torque control technique is presented.

Methods: Synchronous machine drive system requires uninterrupted and more secure conditions during operations.

Results: Therefore the diagnostic of voltage source inverter and synchronous motor faults are needed for improving system availability.

Conclusion: This article aims to propose an accurate open-phase fault detection and fault-tolerant inverter of a permanent magnet synchronous motor using direct torque control technique. Experimental implementation is carried out on powerful dSpace DS1104. The validity of the proposed method has been experimentally verified.

Keywords: Current signature analysis, Direct Torque Control (DTC), fault tolerant inverter, open phase fault, Permanent Magnet Synchronous Motor (PMSM).

Graphical Abstract

[1]
O. Saadaoui, A. Khlaief, M. Abassi, A. Chaari, and M. Boussak, A sliding mode observer for high-performance sensorless control of PMSM with initial rotor position detection.Internat. J. Cont DOI: 10.1080/00207179.2016.1181788, 2016., .
[2]
A. Khlaief, O. Saadaoui, M. Boussak, and A. Chaari, “Implementation of stator resistance adaptation for sensorless speed control of IPMSM drive based on nonlinear position observer”, Internat. Conf. Electric. Mach., ICEM, 2016, pp. 1071-1077. DOI:10.1109/ICELMACH.2016.7732658, 2016.
[3]
S. Yi, Z. Ping, T. Peilun, W. Fan, and W. Pengfei, A five-phase 20-slot/18-pole PMSM for electric vehicles COMPEL: Internat J. Computat. Mathemat. Electric. Electron. Eng., pp. 439-455, 2016. .
[4]
A. Khlaief, M. Boussak, and M. Gossa, "Model reference adaptive system based adaptive speed estimation for sensorless vector control with initial rotor position estimation for interior permanent magnet synchronous motor drive", Electr. Power Compon. Syst., pp. 47-74, 2013.
[5]
A. Khlaief, M. Boussak, and M. Gossa, "Open phase faults detection in PMSM drives based on current signature analysis", Internat. Conf. Electric. Mach. Conf., IEEE XIXth Internat., 2010pp. 418-422
[6]
M. Moujahed, H.B. Azza, K. Frifta, M. Jemli, and M. Boussak, Fault detection and fault tolerant control of power converter Fed PMSM Springer, vol. 98, no. 2, pp. 121-131, 2016.
[7]
M. Abassi, A. Khlaief, O. Saadaoui, A. Chaari, and M. Boussak, "Performance analysis of FOC and DTC for PMSM drives using SVPWM Technique", 16th Internat. Conf. Automat. Cont. Comput. Engineering, pp. 228-233.
[8]
T. Gallah, B. Bouzidi, and A. Masmoudi, DTC of reconfigured three level inverter fed IM drives following a leg failure COMPEL: Internat. J. Comput. Mathem. Electric. Electron. Eng., pp.764-781, 2016. .
[9]
A. Adam, and K. Gulez, A new sensorless hysteresis direct torque control algorithm for PMSM with minimum torque ripples The Internat. J. Computat. Mathem. Electric. Electron. Eng., pp. 437- 453, 2009.
[10]
A. Sikorshi, and R. Grodzki, A new DTC control for PMSM with torque ripple minimization and constant switching frequency Internat. J. Comput. Mathem. Electric. Electron. Eng., pp. 1069- 1081, 2011. .
[11]
M.A.S.K. Khan, and M.A. Rahman, "Development and implementation of a novel fault diagnostic and protection technique for IPM motor drives", IEEE Trans. Ind. Electron., pp. 85-92, 2009.
[12]
G.H. Foo, X.B. Zhang, and D.M. Vilathgamuwa, A sensor fault detection and isolation method in interior permanent magnet synchronous motor drives based on an extended Kalman filter., IEEE Transact. on Indust. Electron, 2013, pp. 3485-3495.
[13]
A. Khlaief, M. Boussak, and A. Chaari, "A real-time open phase faults detection for IPMSM drives based on discrete fourier transform phase analysis", Internat. Conference on Electrical Engineering and Software Applications, 2013pp. 1-6
[14]
M. Jannati, N.N. Idris, and M.A. Aziz, "Vector control of star-connected 3-phase induction motor drives under open-phase fault based on rotor flux field-oriented control", Electr. Power Compon. Syst., pp. 2325-2337, 2016.
[15]
T. Benslimane, and T. Abdelkarim, "Open switch fault detection and localization algorithm for three phase shunt active power filter based on two level voltage source inverter in main power supply constant and variable frequency conditions", J. Electr. Electron. Eng. , pp. 841-851, 2009.
[16]
S.M. Dabour, and M.I. Masoud, "“Open-circuit fault detection of five-phase voltage source inverter” In: Proceedings of the 8th IEEE GCC Conference and Exhibition, Muscat, 2015, pp. 1-4",
[17]
H.B. Azza, M. Moujahed, M. Jemli, and M. Boussak, Implementation of improved sliding mode observer and fault tolerant control for a PMSM Drive J. Circ., Syst. Comput., Vol. 16, pp. 1750032_1-1750032, 2017. .
[18]
A. Khlaief, K. Jemli, M. Boussak, and M. Gossa, “Study on inverter’s IGBT fault behavior with permanent magnet synchronous motor’s drive”, Internat. Rev. Electric. Eng. pp. 1580-159, 2011.
[19]
J. Singh, B. Singh, S. Singh, and M. Naim, Investigation of performance parameters of PMSM drives using DTC -SVPWM technique.Student Conf. Eng. Syst pp. 1-6, 2012, .
[20]
K. Jemli, M. Gossa, M. Jemli, and M. Boussak, “Diagnosis of an IGBT inverters weakness in vector controlled induction machines drives. In: Proc. Second Internat. Conf. Sig. Syst. Dec. Inform. Technol. SSD’03–Sousse, Tunisia, March 26-28, 2003, CD-ROM.

Rights & Permissions Print Cite