Abstract
In this paper is presented an overview of the technological barriers faced by the in vivo brain analysis with microelectrodes. Numerous microsensors and enzymatic microbiosensors have been developed for the real time monitoring of neurotransmitters, neuromodulators, drugs and diverse other biological relevant substances. A clear understanding of the working principle, advantages and limitations is essential for the acquisition of valid data in neurological investigations. Some of the aspects presented here refer to: microelectrode insertion and positioning related to possibilities to minimize tissue damage, spatial and temporal resolution of the measurements, actual controversies in data interpretation and sensor calibration, simultaneous detection of multiple analytes, interferences and state of the art in the development of wireless devices.
Keywords: Brain in vivo analysis, microelectrodes, microbiosensors, neurotransmitters, neuromodulators
Current Neuropharmacology
Title:Technological Barriers in the Use of Electrochemical Microsensors and Microbiosensors for in vivo Analysis of Neurological Relevant Substances
Volume: 10 Issue: 3
Author(s): Bogdan Bucur
Affiliation:
Keywords: Brain in vivo analysis, microelectrodes, microbiosensors, neurotransmitters, neuromodulators
Abstract: In this paper is presented an overview of the technological barriers faced by the in vivo brain analysis with microelectrodes. Numerous microsensors and enzymatic microbiosensors have been developed for the real time monitoring of neurotransmitters, neuromodulators, drugs and diverse other biological relevant substances. A clear understanding of the working principle, advantages and limitations is essential for the acquisition of valid data in neurological investigations. Some of the aspects presented here refer to: microelectrode insertion and positioning related to possibilities to minimize tissue damage, spatial and temporal resolution of the measurements, actual controversies in data interpretation and sensor calibration, simultaneous detection of multiple analytes, interferences and state of the art in the development of wireless devices.
Export Options
About this article
Cite this article as:
Bucur Bogdan, Technological Barriers in the Use of Electrochemical Microsensors and Microbiosensors for in vivo Analysis of Neurological Relevant Substances, Current Neuropharmacology 2012; 10 (3) . https://dx.doi.org/10.2174/157015912803217350
DOI https://dx.doi.org/10.2174/157015912803217350 |
Print ISSN 1570-159X |
Publisher Name Bentham Science Publisher |
Online ISSN 1875-6190 |

- Author Guidelines
- Bentham Author Support Services (BASS)
- Graphical Abstracts
- Fabricating and Stating False Information
- Research Misconduct
- Post Publication Discussions and Corrections
- Publishing Ethics and Rectitude
- Increase Visibility of Your Article
- Archiving Policies
- Peer Review Workflow
- Order Your Article Before Print
- Promote Your Article
- Manuscript Transfer Facility
- Editorial Policies
- Allegations from Whistleblowers
- Announcements
- Forthcoming Thematic Issues
Related Articles
-
Use of Medication in Coronary Imaging by CT
Current Medical Imaging Biologics for Extraintestinal Manifestations of IBD
Current Drug Targets Anabolic Androgenic Steroid (AAS) Related Deaths: Autoptic, Histopathological and Toxicological Findings
Current Neuropharmacology Aqueous Extract of Argania spinosa L. Fruits Ameliorates Diabetes in Streptozotocin-Induced Diabetic Rats
Cardiovascular & Hematological Agents in Medicinal Chemistry Herbal Oils for Treatment of Chronic and Diabetic Wounds: A Systematic Review
Current Diabetes Reviews Coronary Artery Disease and Endothelial Dysfunction: Novel Diagnostic and Therapeutic Approaches
Current Medicinal Chemistry Tear Film, Conjunctival and Corneal Modifications Induced by Glaucoma Treatment
Current Medicinal Chemistry Vasopressin in Liver Disease – Should We Turn On or Off?
Current Clinical Pharmacology Therapeutic Effects and Mechanisms of Action of Cyclosporine A Ophthalmic Solution in the Treatment of Vernal Keratoconjunctivitis
Current Pharmaceutical Analysis Mechanisms, Prevention and Treatment of Distal Embolization
Current Pharmaceutical Design Use of Contrast Echocardiography in Intensive Care and at the Emergency Room
Current Cardiology Reviews About Mechanism of Gas Transport Function and Side Reactions of Perfluorocarbon Nano-dispersions
Current Bionanotechnology (Discontinued) PET Imaging and Coronary Circulatory Function: Non-Invasive Mechanistic Insights and Cardiovascular Prognosis
Current Cardiology Reviews Glycoprotein Targeting and Other Applications of Lectins in Biotechnology
Current Protein & Peptide Science Pannexin Channels: The Emerging Therapeutic Targets
Current Drug Targets Purinergic Signalling and Endothelium
Current Vascular Pharmacology Stable Angina Pectoris: Current Medical Treatment
Current Pharmaceutical Design Evaluation of Cell Tolerability of a Series of Lipoamino Acids Using Biological Membranes and a Biomembrane Model.
Current Drug Delivery The Role of Heat Shock Protein 90 and Endothelial Nitric Oxide Synthase Signaling in Cardiovascular Therapy
Current Signal Transduction Therapy Neuroprotective Effects of Intravenous Anesthetics: A New Critical Perspective
Current Pharmaceutical Design