Generic placeholder image

Current Radiopharmaceuticals

Editor-in-Chief

ISSN (Print): 1874-4710
ISSN (Online): 1874-4729

Research Article

Assessment of Radiation Exposure Dose for Nuclear Medicine Workers from 18F-FDG, 99mTc MDP, and 99mTc

Author(s): Abdulrahman M. Al-esaei, Magdy M. Khalil, Raed M. El Shazly, Amr M.I. Kany, Emran Eisa Saleh* and Sharif Elmaghraby

Volume 15, Issue 4, 2022

Published on: 17 August, 2022

Page: [320 - 326] Pages: 7

DOI: 10.2174/1874471015666220413114927

Price: $65

Abstract

Background: Nuclear medicine or diagnostic radiology personnel are always exposed to low-level radiation from radionuclides used in medical diagnostics, which lead to potential biological hazards or effects.

Objective: External exposure for workers in two nuclear medicine centers was measured by recruiting 120 patients.

Methods: Three nuclear medicine examinations were performed using F18-FDG PET/CT,99mTc- MDP bones scan, and 99mTc thyroid scan by a digital radiation dosimeter.

Results: The average received accumulative radiation dose for workers was found to be 0.838±0.17, 0.527±0.11, and 0.270±0.05 µSv for F18-FDG PET/CT, 99mTc-MDP bones scan, and 99mTc thyroid scan, respectively. The annual effective dose for workers was estimated to be 2.09±0.42, 1.34±0.27, and 0.68±0.14 mSv, respectively. Moreover, the average patient-to-staff dose coefficients were found to be 0.024±0.005, 0.003±0.001, and 0.007±0.002 µSv m2/MBq h for F18- FDG PET/CT, 99mTc-MDP bones scan, and 99mTc thyroid scan, respectively.

Conclusion: It is clear from the results that the radiation doses received by workers during the nuclear medicine imaging examinations were less than the doses recommended by the International Commission on Radiological Protection (ICRP) for such examinations.

Keywords: Nuclear medicine, PET/CT, Tc-99, radiation dose, patients, F18-FDG.

Graphical Abstract

[1]
Fathy, M.; Khalil, M.M.; Elshemey, W.M.; Mohamed, H.S. Occupational radiation dose to nuclear medicine staff due to TC99m, F18-FDG PET and therapeutic I-131 based examinations. Radiat. Prot. Dosimetry, 2019, 186(4), 443-451.
[http://dx.doi.org/10.1093/rpd/ncz046] [PMID: 30989207]
[2]
United nation Scientific committee on the effects of atomic radiation. Sources and effects of ionizing radiation. Annex B: Exposures from natural radiation sources. 2008, available from: www.unscear.org
[3]
National council on radiation protection and measurements. Use of personal monitors to estimate effective dose equivalent and effective dose to workers for external exposure to low-LET radiation. NCRP 1995, Report No.122, 1995.
[4]
McElroy, N.L. Worker dose analysis based on real time dosimetry. Health Phys., 1998, 74(5), 608-609.
[http://dx.doi.org/10.1097/00004032-199805000-00009] [PMID: 9570165]
[5]
Zito, F.; Eulisse, G.; Rozza, M. Dosimetric evaluation for workers operating into a PET department. sixth European ALARA Network workshop on occupational exposure optimization in the medical field and radiopharmaceutical industry.madrid., Spain, 2002.
[6]
Adliene, D.; Griciene, B.; Skovorodko, K.; Laurikaitiene, J.; Puiso, J. Occupational radiation exposure of health professionals and cancer risk assessment for Lithuanian nuclear medicine workers. Environ. Res., 2020, 183, 109144.
[http://dx.doi.org/10.1016/j.envres.2020.109144] [PMID: 32028181]
[7]
Alkhorayef, M.; Fareed, H.; Mayhoub, H.S.; Sulieman, A.; Al-Mohammed, H.I.; Almuwannis, M.; Kappas, C.; Bradley, D.A. Assessment of occupational exposure and radiation risks in nuclear medicine departments. Radiat. Phys. Chem., 2020, 170, 108529.
[http://dx.doi.org/10.1016/j.radphyschem.2019.108529]
[8]
Alkhorayef, M.; Sulieman, A.; Mohamed-Ahmed, M.; Al-Mohammed, H.I.; Alkhomashi, N.; Sam, A.K.; Bradley, D.A. Staff and ambient radiation dose resulting from therapeutic nuclear medicine procedures. Appl. Radiat. Isot., 2018, 141, 270-274.
[http://dx.doi.org/10.1016/j.apradiso.2018.07.014] [PMID: 30145016]
[9]
Sulieman, A.; Abdelrazig, H.; Al-Mohammed, M.; Alkhorayef, B.; Alonazi, I.I.; Suliman, N.; Abuhadi, D. Bradley. Radiogenic risks to patients and staff from fluoro-assisted therapeutic cardiac catheterizations. Radiat. Phys. Chem., 2020, 167, 108348.
[http://dx.doi.org/10.1016/j.radphyschem.2019.108348]
[10]
Nassef, M.H.; Kinsara, A.A. Occupational radiation dose for medical workers at a university hospital. J. Taibah Univ. Sci., 2017, 11(6), 1259-1266.
[http://dx.doi.org/10.1016/j.jtusci.2017.01.003]
[11]
Madsen, M.T.; Anderson, J.A.; Halama, J.R.; Kleck, J.; Simpkin, D.J.; Votaw, J.R.; Wendt, R.E., III; Williams, L.E.; Yester, M.V. AAPM Task Group 108: PET and PET/CT shielding requirements. Med. Phys., 2006, 33(1), 4-15.
[http://dx.doi.org/10.1118/1.2135911] [PMID: 16485403]
[12]
Eschner, W.; Vogg, R.; Braunlich, I.; Mack, R.; Wagner, H.S. Incorporation risks for workers in PET centeres. Radiat. Prot. Dosimetry, 2000, 89(3), 211-213.
[http://dx.doi.org/10.1093/oxfordjournals.rpd.a033066]
[13]
Biran, T.; Weininger, J.; Malchi, S.; Marciano, R.; Chisin, R. Measurements of occupational exposure for a technologist performing 18F FDG PET scans. Health Phys., 2004, 87(5), 539-544.
[http://dx.doi.org/10.1097/01.HP.0000137180.85643.9d] [PMID: 15551792]
[14]
Roberts, F.O.; Gunawardana, D.H.; Pathmaraj, K.; Wallace, A. U, P.L.; Mi, T.; Berlangieri, S.U.; O’Keefe, G.J.; Rowe, C.C.; Scott, A.M. Radiation dose to PET technologists and strategies to lower occupational exposure. J. Nucl. Med. Technol., 2005, 33(1), 44-47.
[PMID: 15731021]
[15]
Zeff, B.W.; Yester, M.V. Patient self-attenuation and technologist dose in positron emission tomography. Med. Phys., 2005, 32(4), 861-865.
[http://dx.doi.org/10.1118/1.1869552] [PMID: 15895568]

Rights & Permissions Print Cite