Generic placeholder image

Current Medical Imaging

Editor-in-Chief

ISSN (Print): 1573-4056
ISSN (Online): 1875-6603

Research Article

Radiation Dose Reduction in Head and Neck Computed Tomography Angiography

Author(s): Ying-Jia Zhao, Xi Ma, Ya-Ting Zheng, Zi-Wei Zuo, Ying-Jin Xu, Jia-Ning Wang, Xiao-Ping Yin* and Bu-Lang Gao

Volume 18, Issue 7, 2022

Published on: 28 March, 2022

Article ID: e180122200346 Pages: 7

DOI: 10.2174/1573405618666220118160535

Price: $65

conference banner
Abstract

Background and Aim: The study aims to investigate the feasibility of further radiation dose reduction via the application of a high iodine delivery rate combined with automatic current modulation technology (high noise index) in head and neck computed tomography angiography.

Methods: Sixty-four patients who underwent routine head and neck computed tomographic angiography were randomly divided into two groups: a low-dose group of 32 cases and an ultra-low-dose group of 32 cases. The same image reconstruction technique was applied in both groups using the 50% adaptive statistical iterative reconstruction method. Quantitative and qualitative image quality assessment of the carotid artery, computed tomographic dose index volume, dose length product, and effective dose of the two groups were analyzed.

Results: The two groups were not significantly (P>0.05) different in age, gender, and body mass index. Significant (P<0.001) reduction of radiation dose was observed in all the parameters of computed tomographic dose index volume (18.12%), dose length product (19.91%), and effective dose (19.84%) in the ultra-low-dose group. Quantitative and qualitative image assessment produced similar results between the two groups, except for the higher mean vascular computed tomographic values found in the ultra-low dose group.

Conclusion: Application of a higher iodine delivery rate combined with automatic current modulation technology (high noise index) in an existing low tube voltage protocol can further decrease the radiation dose and the total volume of contrast agent while maintaining similar image quality for patients undergoing computed tomography angiography of the head and neck, which can be recommended as the conventional scanning method.

Keywords: Iodine delivery rate, contrast agent, radiographic image enhancement, radiation dose, computed tomography angiography, automatic current modulation technology.

Graphical Abstract

[1]
Magge R, Lau BC, Soares BP, et al. Clinical risk factors and CT imaging features of carotid atherosclerotic plaques as predictors of new incident carotid ischemic stroke: A retrospective cohort study. AJNR Am J Neuroradiol 2013; 34(2): 402-9.
[http://dx.doi.org/10.3174/ajnr.A3228] [PMID: 22859283]
[2]
Shankar JJ, Lum C, Chakraborty S, Dos Santos M. Cerebral vascular malformations: Time-resolved CT angiography compared to DSA. Neuroradiol J 2015; 28(3): 310-5.
[http://dx.doi.org/10.1177/1971400915589682] [PMID: 26246101]
[3]
Pearce MS, Salotti JA, Little MP, et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: A retrospective cohort study. Lancet 2012; 380(9840): 499-505.
[http://dx.doi.org/10.1016/S0140-6736(12)60815-0] [PMID: 22681860]
[4]
Singh S, Kalra MK, Sung MK, Back A, Blake MA. Radiation dose reduction with application of non-linear adaptive filters for abdominal CT. World J Radiol 2012; 4(1): 21-8.
[http://dx.doi.org/10.4329/wjr.v4.i1.21] [PMID: 22328968]
[5]
Sun Y, Hua Y, Wang M, et al. Evaluation of a high concentrated contrast media injection protocol in combination with low tube current for dose reduction in coronary computed tomography angiography: A randomized, two-center prospective study. Acad Radiol 2017; 24(12): 1482-90.
[http://dx.doi.org/10.1016/j.acra.2017.07.001] [PMID: 28800951]
[6]
Ning P, Zhu S, Shi D, Guo Y, Sun M. X-ray dose reduction in abdominal computed tomography using advanced iterative reconstruction algorithms. PLoS One 2014; 9(3): e92568.
[http://dx.doi.org/10.1371/journal.pone.0092568] [PMID: 24664174]
[7]
Kaza RK, Platt JF, Goodsitt MM, et al. Emerging techniques for dose optimization in abdominal CT. Radiographics 2014; 34(1): 4-17.
[http://dx.doi.org/10.1148/rg.341135038] [PMID: 24428277]
[8]
Chen-Hong Zang JZ, Zhang Y-T. The application of anto-mA low-kV CT scanning on head and neck CT angiography: A feasibility study. J Tianjin Med Univ 2010; 16: 322-5.
[9]
Wang Q, Zhao X, Song J, et al. The application of automatic tube current modulation (ATCM) on image quality and radiation dose at abdominal computed tomography (CT): A phantom study. J XRay Sci Technol 2013; 21(4): 453-64.
[http://dx.doi.org/10.3233/XST-130403] [PMID: 24191984]
[10]
Heusch P, Lanzman RS, Aissa J, et al. Evaluation of a high iodine delivery rate in combination with low tube current for dose reduction in pulmonary computed tomography angiography. J Thorac Imaging 2014; 29(5): 293-7.
[http://dx.doi.org/10.1097/RTI.0000000000000099] [PMID: 25100138]
[11]
Matsuoka S, Hunsaker AR, Gill RR, et al. Vascular enhancement and image quality of MDCT pulmonary angiography in 400 cases: Comparison of standard and low kilovoltage settings. AJR Am J Roentgenol 2009; 192(6): 1651-6.
[http://dx.doi.org/10.2214/AJR.08.1730] [PMID: 19457830]
[12]
Romanyukha A, Folio L, Lamart S, Simon SL, Lee C. Body size-specific effective dose conversion coefficients for CT scans. Radiat Prot Dosimetry 2016; 172(4): 428-37.
[http://dx.doi.org/10.1093/rpd/ncv511] [PMID: 26755767]
[13]
Brenner DJ, Hall EJ. Computed tomography-an increasing source of radiation exposure. N Engl J Med 2007; 357(22): 2277-84.
[http://dx.doi.org/10.1056/NEJMra072149] [PMID: 18046031]
[14]
Lee CI, Haims AH, Monico EP, Brink JA, Forman HP. Diagnostic CT scans: Assessment of patient, physician, and radiologist awareness of radiation dose and possible risks. Radiology 2004; 231(2): 393-8.
[http://dx.doi.org/10.1148/radiol.2312030767] [PMID: 15031431]
[15]
Kennedy TC, Miller Y, Prindiville S. Screening for lung cancer revisited and the role of sputum cytology and fluorescence bronchoscopy in a high-risk group. Chest 2000; 117(4)(Suppl. 1): 72S-9S.
[http://dx.doi.org/10.1378/chest.117.4_suppl_1.72S] [PMID: 10777459]
[16]
Stacul F, van der Molen AJ, Reimer P, et al. Contrast Media Safety Committee of European Society of Urogenital Radiology (ESUR). Contrast induced nephropathy: Updated ESUR Contrast Media Safety Committee guidelines. Eur Radiol 2011; 21(12): 2527-41.
[http://dx.doi.org/10.1007/s00330-011-2225-0] [PMID: 21866433]
[17]
Slovis TL. The ALARA concept in pediatric CT: Myth or reality? Radiology 2002; 223(1): 5-6.
[http://dx.doi.org/10.1148/radiol.2231012100] [PMID: 11930041]
[18]
Gay F, Pavia Y, Pierrat N, Lasalle S, Neuenschwander S, Brisse HJ. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: Phantom study and clinical experience on chest and abdomen CT. Eur Radiol 2014; 24(1): 102-11.
[http://dx.doi.org/10.1007/s00330-013-2982-z] [PMID: 23995879]
[19]
You J, Dai Y, Huang N, et al. Low-dose computed tomography with adaptive statistical iterative reconstruction and low tube voltage in craniocervical computed tomographic angiography: Impact of body mass index. J Comput Assist Tomogr 2015; 39(5): 774-80.
[http://dx.doi.org/10.1097/RCT.0000000000000260] [PMID: 25938211]
[20]
Zhao L, Winklhofer S, Yang Z, Wang K, He W. Optimal adaptive statistical iterative reconstruction percentage in dual-energy monochromatic CT portal venography. Acad Radiol 2016; 23(3): 337-43.
[http://dx.doi.org/10.1016/j.acra.2015.11.004] [PMID: 26777591]
[21]
Nakamoto A, Kim T, Hori M, et al. Clinical evaluation of image quality and radiation dose reduction in upper abdominal computed tomography using model-based iterative reconstruction; comparison with filtered back projection and adaptive statistical iterative reconstruction. Eur J Radiol 2015; 84(9): 1715-23.
[http://dx.doi.org/10.1016/j.ejrad.2015.05.027] [PMID: 26037266]
[22]
Singh S, Kalra MK, Hsieh J, et al. Abdominal CT: Comparison of adaptive statistical iterative and filtered back projection reconstruction techniques. Radiology 2010; 257(2): 373-83.
[http://dx.doi.org/10.1148/radiol.10092212] [PMID: 20829535]
[23]
Brotis AG, Paterakis KN, Tsiamalou PM, Fountas KN, Hahjigeorgiou GM, Karavelis A. Instrumented posterior lumbar fusion outcomes for lumbar degenerative disorders in a southern European, semirural population. J Spinal Disord Tech 2010; 23(7): 444-50.
[http://dx.doi.org/10.1097/BSD.0b013e3181c9828e] [PMID: 20921872]
[24]
Chen JH, Jin EH, He W, Zhao LQ. Combining automatic tube current modulation with adaptive statistical iterative reconstruction for low-dose chest CT screening. PLoS One 2014; 9(4): e92414.
[http://dx.doi.org/10.1371/journal.pone.0092414] [PMID: 24691208]
[25]
Heiland S, Erb G, Ziegler S, Krix M. Where contrast agent concentration really matters - A comparison of CT and MRI. Invest Radiol 2010; 45(9): 529-37.
[http://dx.doi.org/10.1097/RLI.0b013e3181ea703d] [PMID: 20661143]
[26]
Iezzi R, Santoro M, Marano R, et al. Low-dose multidetector CT angiography in the evaluation of infrarenal aorta and peripheral arterial occlusive disease. Radiology 2012; 263(1): 287-98.
[http://dx.doi.org/10.1148/radiol.11110700] [PMID: 22332067]
[27]
Aschoff AJ, Catalano C, Kirchin MA, Krix M, Albrecht T. Low radiation dose in computed tomography: The role of iodine. Br J Radiol 2017; 90(1076): 20170079.
[http://dx.doi.org/10.1259/bjr.20170079] [PMID: 28471242]
[28]
Schwarz F, Grandl K, Arnoldi A, et al. Lowering radiation exposure in CT angiography using automated tube potential selection and optimized iodine delivery rate. AJR Am J Roentgenol 2013; 200(6): W628-34.
[http://dx.doi.org/10.2214/AJR.12.9635] [PMID: 23701094]
[29]
Zhang Q, Mi H, Shi X, et al. Higher iodine concentration enables radiation dose reduction in coronary CT angiography. Acad Radiol 2021; 28(8): 1072-80.
[http://dx.doi.org/10.1016/j.acra.2020.05.012] [PMID: 32553279]
[30]
Thomsen HS, Morcos SK, Erley CM, et al. Investigators in the abdominal computed tomography: IOMERON 400 versus VISIPAQUE 320 Enhancement (ACTIVE) Study. The ACTIVE Trial: Comparison of the effects on renal function of iomeprol-400 and iodixanol-320 in patients with chronic kidney disease undergoing abdominal computed tomography. Invest Radiol 2008; 43(3): 170-8.
[http://dx.doi.org/10.1097/RLI.0b013e31815f3172] [PMID: 18301313]

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy