Abstract
Liquid needle-free injectors employ high-velocity liquid jets to deliver drugs and vaccines. Several parameters are critical to the injection quality: nozzle diameter, volume of drug delivered, ampoule diameter, pressure that drives liquid volume, and impact gap (distance between piston and trigger). A physical model is presented to calculate the stagnation pressure of the injection jet. Two types of the injection systems were tested: a spring-powered system and a voice-coil powered system. The calculation results show that the variation of stagnation pressure with time matches the experimental measurement under the same system conditions. The maximum stagnation pressure determines whether the jet can erode and penetrate into the skin. The maximum stagnation pressure was calculated under three conditions: different volumes, different spring rates and different ampoule diameters, and the results were compared with the experimental measurements. The experiments validated the physical model.
Keywords: Liquid needle-free injection, modeling, stagnation pressure, jet, voice-coil, Resistant Force, Ring Seal
Drug Delivery Letters
Title: Stagnation Pressure in Liquid Needle-Free Injection: Modeling and Experimental Validation
Volume: 1 Issue: 2
Author(s): Kai Chen, Hua Zhou, Ji Li and Gary J. Cheng
Affiliation:
Keywords: Liquid needle-free injection, modeling, stagnation pressure, jet, voice-coil, Resistant Force, Ring Seal
Abstract: Liquid needle-free injectors employ high-velocity liquid jets to deliver drugs and vaccines. Several parameters are critical to the injection quality: nozzle diameter, volume of drug delivered, ampoule diameter, pressure that drives liquid volume, and impact gap (distance between piston and trigger). A physical model is presented to calculate the stagnation pressure of the injection jet. Two types of the injection systems were tested: a spring-powered system and a voice-coil powered system. The calculation results show that the variation of stagnation pressure with time matches the experimental measurement under the same system conditions. The maximum stagnation pressure determines whether the jet can erode and penetrate into the skin. The maximum stagnation pressure was calculated under three conditions: different volumes, different spring rates and different ampoule diameters, and the results were compared with the experimental measurements. The experiments validated the physical model.
Export Options
About this article
Cite this article as:
Chen Kai, Zhou Hua, Li Ji and J. Cheng Gary, Stagnation Pressure in Liquid Needle-Free Injection: Modeling and Experimental Validation, Drug Delivery Letters 2011; 1 (2) . https://dx.doi.org/10.2174/2210304x11101020097
DOI https://dx.doi.org/10.2174/2210304x11101020097 |
Print ISSN 2210-3031 |
Publisher Name Bentham Science Publisher |
Online ISSN 2210-304X |
- Author Guidelines
- Graphical Abstracts
- Fabricating and Stating False Information
- Research Misconduct
- Post Publication Discussions and Corrections
- Publishing Ethics and Rectitude
- Increase Visibility of Your Article
- Archiving Policies
- Peer Review Workflow
- Order Your Article Before Print
- Promote Your Article
- Manuscript Transfer Facility
- Editorial Policies
- Allegations from Whistleblowers
Related Articles
-
Anticancer Therapeutic Strategies Based on CDK Inhibitors
Current Pharmaceutical Design Asymmetric Dimethylarginine: Clinical Significance and Novel Therapeutic Approaches
Current Medicinal Chemistry Delivery of Therapeutic Proteins: Challenges and Strategies
Current Drug Targets Insights into the Association of Vitamin D Deficiency with Parathyroid Hormone Levels with Relevance to Renal Function and Insulin Resistance
Current Nutrition & Food Science Pathogenesis and Subtype of Intracerebral Hemorrhage (ICH) and ICH Score Determines Prognosis
Current Neurovascular Research The Role of Inflammation in Epicardial Adipose Tissue in Heart Diseases
Current Pharmaceutical Design Editorial (Hot Topic: Neurodegeneration: The First IBRO-Middle East Neuroscience Conference)
Current Alzheimer Research Impact of Bread Made from Mix Cereals and Pulses on the Glycemic Profile in Type 2 Diabetic Patients - A Randomized Controlled Trial
Current Nutrition & Food Science Pharmacotherapy in Type 2 Diabetes: A Functional Schema for Drug Classification
Current Diabetes Reviews Non-Analgesic Effects of Opioids: Opioid-induced Nausea and Vomiting: Mechanisms and Strategies for their Limitation
Current Pharmaceutical Design Genome Study of Kidney Disease in the Age of Post Genome-Sequencing
Endocrine, Metabolic & Immune Disorders - Drug Targets Stroke Prevention: From Available Antiplatelet Drugs to Novel Molecular Targets
Current Drug Targets A Brief History of ‘Lone’ Atrial Fibrillation: From ‘A Peculiar Pulse Irregularity’ to a Modern Public Health Concern
Current Pharmaceutical Design Treatment of Hypertensive Complications in Pregnancy
Current Pharmaceutical Design Profiling the Shear Stress of Atherosclerosis; A Genomic View
Current Genomics One-Compound-Multi-Target: Combination Prospect of Natural Compounds with Thrombolytic Therapy in Acute Ischemic Stroke
Current Neuropharmacology Ferritin and Percent Transferrin Saturation Levels Predict Type 2 Diabetes Risk and Cardiovascular Disease Outcomes
Current Diabetes Reviews Prognostic Parameters for Symptomatic Intracranial Hemorrhage after Intravenous Thrombolysis in Acute Ischemic Stroke in an Asian Population
Current Neurovascular Research Meet Our Editorial Board Member
Current Cancer Drug Targets Hyperhomocysteinemia and Sudden Cardiac Death: Potential Arrhythmogenic Mechanisms
Current Vascular Pharmacology