The Diverse Utility of Contrast Media Delivery and Dosing During Computed Tomography: An International Assessment of Knowledge and Practices

Author(s): Mohammad Rawashdeh*, Daniah Kashabash, Praveen Kumar and Charbel Saade

Volume 17, Issue 4, 2024

Published on: 03 April, 2024

Page: [364 - 370] Pages: 7

DOI: 10.2174/0118744710293946240325051232

Price: $65

Abstract

Background: Despite the escalated production rate, the Iodinated Contrast Media (ICM) shortage continues, and demand outweighs supply.

Aim: The aim of this study is to investigate the knowledge and practice of ICM delivery in computed tomography (CT) among radiographers and radiologic technologists worldwide.

Methods: An IRB-approved cross-sectional survey used Google Forms for data collection. It involved 94 CT radiographers from 27 countries and was divided into five sections. The first section gathered demographic information, followed by sections on experience, self-assessment of ICM reactions, and delivery technique. The third section explored ICM knowledge and its relation to CT parameters. The fourth and fifth sections focus on practices during pulmonary angiography CT and renal CT scans. Data analysis involved descriptive statistics, the Chi- Square test, and ANOVA.

Results: Knowledge was assessed with seven questions, and a score of at least 3.5 was needed for categorization. The median score was two, indicating low knowledge. Specifically, 64.9% of the participants scored lower than the two scores. Years of experience are strongly correlated with the level of knowledge, with 51.6% of radiographers having more than 10 years of experience demonstrating adequate knowledge. 41.7% of respondents demonstrated adequate knowledge when their duty was focused on CT. Furthermore, wide practice variability exists in all CT pulmonary angiography protocols among radiographers with adequate and inadequate knowledge.

Conclusion: Inexperienced individuals showed knowledge gaps, leading to varied practices and highlighting the need for educational programs. The study underscores establishing standardized Protocols and Practice Guidelines (PPGs) for contrast media administration in Radiology Departments. Additionally, it emphasizes the importance of regular training programs, and international knowledge sharing. The potential for self-selection bias in the online survey sample is highlighted.

[1]
Patel, P.R.; De Jesus, O.C.T. Scan; StatPearls Publishing: Treasure Island, 2023.
[2]
Huseinagić, H.; Efendić, A.; Rušidović, I. 3D computed tomography intravascular endoscopy. Pol. J. Radiol., 2023, 88(1), 435-444.
[http://dx.doi.org/10.5114/pjr.2023.131000] [PMID: 37808171]
[3]
Gunderman, R.B. The medical community’s changing vision of the patient: The importance of radiology. Radiology, 2005, 234(2), 339-342.
[http://dx.doi.org/10.1148/radiol.2342040892] [PMID: 15670989]
[4]
Cundari, G. Saving contrast media in coronary ct angiography with photon-counting detector CT. Acad. Radiol., 2023, 31(1), 212-220.
[PMID: 37532596]
[5]
Kutleša, Z.; Jerković, K.; Ordulj, I.; Budimir Mršić, D. The effect of contrast media on CT measures of bone mineral density: A systematic review. Skeletal Radiol., 2023, 52(4), 687-694.
[http://dx.doi.org/10.1007/s00256-022-04222-2] [PMID: 36329255]
[6]
ACR. Contrast media shortage resources., 2022. Available from: https://www.acr.org/Clinical-Resources/Contrast-Manual/Contrast-Shortage-Information (Accessed on 2023 10).
[7]
Schwartz, S.; Watts, L. Contrast media shortages - medical imaging considerations: A literature review. J. Med. Imaging Radiat. Sci., 2024, 4(23), 1939-8654.
[8]
Cavallo, J.J.; Pahade, J.K. Practice management strategies for imaging facilities facing an acute iodinated contrast media shortage. AJR Am. J. Roentgenol., 2022, 219(4), 666-670.
[http://dx.doi.org/10.2214/AJR.22.27969] [PMID: 35549445]
[9]
Morzycki, A.; Bhatia, A.; Murphy, K.J. Adverse reactions to contrast material: A canadian update. Can. Assoc. Radiol. J., 2017, 68(2), 187-193.
[http://dx.doi.org/10.1016/j.carj.2016.05.006] [PMID: 27745988]
[10]
Chiu, T.M.; Chu, S.Y. Hypersensitivity reactions to iodinated contrast media. Biomedicines, 2022, 10(5), 1036.
[http://dx.doi.org/10.3390/biomedicines10051036] [PMID: 35625773]
[11]
Thomsen, H.S.; Bush, W.H., Jr Adverse effects of contrast media: Incidence, prevention and management. Drug Saf., 1998, 19(4), 313-324.
[http://dx.doi.org/10.2165/00002018-199819040-00006] [PMID: 9804445]
[12]
Rawashdeh, M.; McEntee, M.F.; Zaitoun, M.; Abdelrahman, M.; Brennan, P.; Alewaidat, H.; Lewis, S.; Saade, C. Knowledge and practice of computed tomography exposure parameters amongst radiographers in Jordan. Comput. Biol. Med., 2018, 102, 132-137.
[http://dx.doi.org/10.1016/j.compbiomed.2018.09.020] [PMID: 30278337]
[13]
Niell, B.L.; Vartanians, V.M.; Halpern, E.P. Improving education for the management of contrast reactions: An online didactic model. J. Am. Coll. Radiol., 2014, 11(2), 185-192.e2.
[http://dx.doi.org/10.1016/j.jacr.2013.06.006] [PMID: 24387957]
[14]
Zein-El-Dine, S.; Bou Akl, I.; Mohamad, M.; Chmaisse, A.; Chahwan, S.; Asmar, K.; El-Merhi, F.; Saade, C. Split-bolus contrast injection protocol enhances the visualization of the thoracic vasculature and reduced radiation dose during chest CT. Br. J. Radiol., 2018, 91(1092), 20180509.
[http://dx.doi.org/10.1259/bjr.20180509] [PMID: 30160182]
[15]
Qureshi, A.I.; Grintal, A.; DeGaetano, A.C.; Goren, M.; Lodhi, A.; Golan, D.; Hassan, A.E. Effect of radiographic contrast media shortage on stroke evaluation in the United States. AJNR Am. J. Neuroradiol., 2023, 44(8), 901-907.
[http://dx.doi.org/10.3174/ajnr.A7924] [PMID: 37414453]
[16]
Glaveski, S. Where companies go wrong with learning and development., 2019. Available from: https://hbr.org/2019/10/where-companies-go-wrong-with-learning-and-development (Accessed on 10 OCT 2023).
[17]
Saade, C.; Alsheikh Deeb, I.; Mohamad, M.; Al-Mohiy, H.; El-Merhi, F. Contrast medium administration and image acquisition parameters in renal CT angiography: what radiologists need to know. Diagn. Interv. Radiol., 2016, 22(2), 116-124.
[http://dx.doi.org/10.5152/dir.2015.15219] [PMID: 26728701]
[18]
Saade, C. Cardiovascular CTA applications: Patient-specific contrast formulae; SPIE Medical Imaging, 2013, p. 8673.
[19]
Saade, C.; Bourne, R.; Wilkinson, M.; Brennan, P. Impact of various iodine concentrations of iohexol and iodixanol contrast media on image reconstruction techniques in a vascular-specific contrast media phantom: Quantitative and qualitative image quality assessment. La radiologia medica., 2021, 126(2), 221-230.
[http://dx.doi.org/10.1016/j.jmir.2011.05.002] [PMID: 31051857]
[20]
Saade, C.; Bourne, R.; Wilkinson, M.; Brennan, P. Contrast medium administration and parameters affecting bolus geometry in multidetector computed tomography angiography: An overview. J. Med. Imaging Radiat. Sci., 2011, 42(3), 113-117.
[http://dx.doi.org/10.1016/j.jmir.2011.05.002] [PMID: 31051857]
[21]
Saade, C.; Bourne, R.; El-Merhi, F.; Somanathan, A.; Chakraborty, D.; Brennan, P. An optimised patient-specific approach to administration of contrast agent for CT pulmonary angiography. Eur. Radiol., 2013, 23(11), 3205-3212.
[http://dx.doi.org/10.1007/s00330-013-2919-6] [PMID: 23732690]

Rights & Permissions Print Cite