Modal Analysis and Optimization of Fluid-Structure Coupling for Rotor and Inner Cylinder of Vertical Condensate Pump

Author(s): Xiaofeng He, Xiaofeng Liu, Yunxiang Ma, Chengbin Lu, Yang Wu* and Zhongfu Nie

Volume 17, Issue 5, 2024

Published on: 04 December, 2023

Page: [392 - 399] Pages: 8

DOI: 10.2174/0122127976262378231023080241

Price: $65

Abstract

Background: Low-frequency resonance is one of the common issues encountered during the variable-frequency operation of condensate water pumps. There have been numerous patents and papers proposing solutions to address the low-frequency resonance problem in condensate water pumps. However, the solutions for resonance problems often need to be tailored to specific circumstances.

Methods: Based on the acoustic method, the dynamic model of the rotor and inner cylinder of Jiangsu Guohua Chenjiagang Power Plant 2B condensate pump is established to compare the difference between dry modal and fluid-structure coupling modal, the influence of perpendicularity, concentricity and bearing wear on the natural frequency of rotor is studied.

Results: The rotor is rigid under normal conditions. When the bearing is worn, the frequency of the rotor will be greatly reduced and may fall into the frequency conversion operation range to excite resonance. The deviation of perpendicularity and concentricity will not directly lead to the decrease of rotor modal but will lead to the increase of bearing stress, aggravate bearing wear, and then affect the rotor modal. As the inner cylinder only relies on the fixed support at the top, the structure stiffness is low, which may lead to low-frequency resonance. By adding two support structures at the guide vane, the first-order modal frequency of the inner cylinder can be increased from 3.29 Hz to 28.88 Hz, effectively avoiding the operating frequency range of the system.

Conclusion: This study can guide the optimization of similar pump structures.

[1]
Avor, J.K.; Chang, C.K. Reliability analysis of application of variable frequency drive on condensate pump in nuclear power plant. J. Int. Council. Electr. Eng., 2019, 9(1), 8-14.
[http://dx.doi.org/10.1080/22348972.2018.1564548]
[2]
Ciontu, M.; Popescu, D.; Motocu, M. Analysis of energy efficiency by replacing the throttle valve with variable speed drive condensate pump from E.C. Turceni. 3rd International Symposium on Electrical and Electronics Engineering (ISEEE), Galati, Romania 2010. 16-18 Sep.
[http://dx.doi.org/10.1109/ISEEE.2010.5628495]
[3]
Barie, E.Z.; Chang, C. Application of variable frequency drive on the condensate pump motors of APR1400 nuclear power plants for energy savings. J. Int. Counc. Electr. Eng., 2018, 8(1), 179-189.
[http://dx.doi.org/10.1080/22348972.2018.1515691]
[4]
Li, W.; Li, X.; Niu, Q.; Huang, T.; Zhang, D.; Dong, Y. Analysis and treatment of Free end vibration of condensate pump motor towards ultra-supercritical 660MW turbine. IOP Conf. Ser. Earth Environ. Sci., 2019, 300(4), 042010.
[http://dx.doi.org/10.1088/1755-1315/300/4/042010]
[5]
Simader, V.; Holl, H.J. Reduction of the vibration amplitude with variable excitation frequency. Proc. Appl. Math. Mech., 2021, 20(1), 1-2.
[http://dx.doi.org/10.1002/pamm.202000027]
[6]
Fu, C.; Ren, X.; Yang, Y.; Deng, W. Transient dynamic balancing of rotor system with parametric uncertainties; J Dynamics Control, 2017.
[http://dx.doi.org/10.6052/1672-6553-2017-016]
[7]
Zhao, S.; Ren, X.; Liu, Y.; Lu, K.; Fu, C.; Yang, Y. A dynamic-balancing testing system designed for flexible rotor. Shock Vib., 2021, 2021, 1-17.
[http://dx.doi.org/10.1155/2021/9346947]
[8]
Chai, B.; Zhao, Y.; Wu, Z. Vibration analysis and dynamic balance treatment of condensate pump motor of 390MW gas turbine unit. IOP Conf. Ser. Earth Environ. Sci., 2019, 310(3), 032050.
[http://dx.doi.org/10.1088/1755-1315/310/3/032050]
[9]
Xin, P.; Wu, H.; Gao, J. Performance analysis and control simulation of pneumatic liquid online automatic balancing system for rotating machinery. Int. J. COMADEM, 2018, 21(2), 3-10.
[10]
Su, X.; DeSmidt, H. Imbalance vibration suppression for asymmetric rotors via an enhanced automatic dynamic balancer. J. Sound Vibrat., 2023, 545, 117416.
[http://dx.doi.org/10.1016/j.jsv.2022.117416]
[11]
Goncalves, J.P.S.; Fruett, F. Faults detection and classification in a centrifugal pump from vibration data using markov parameters. In: In: Mechanical Systems and Signal Processing; Elsevier, 2021; 158, p. 107694.
[12]
Wei, X.; Lu, X.; Li, T.; Chen, S. Design on vibration monitoring and fault diagnosis system of large water pump motor. Int Equip Eng Manag, 2021, 26(2), 11.
[13]
Zaccardo, V.M.; Buckner, G.D. Active magnetic dampers for controlling lateral rotor vibration in high-speed rotating shafts. Mech. Syst. Signal Process., 2021, 152, 107445.
[http://dx.doi.org/10.1016/j.ymssp.2020.107445]
[14]
Khang, NV; Trường, LB Active control of damped forced linear vibration systems using twin rotor dampers. 2016.
[15]
Zhang, G.; Xi, G. Vibration control of a time-delayed rotor-active magnetic bearing system by time-varying stiffness. Int. J. Appl. Mech., 2022, 14(4), 2250007.
[http://dx.doi.org/10.1142/S1758825122500077]
[16]
Sondhi, A.K.N. Inspection and maintenance of rotating machinery in fertilizer plant. Indian J. Fert., 2019, 15(5)
[17]
Li, W.; Li, X.; Huang, T.; Niu, Q.; Zhang, D.; Dong, Y. Fault diagnosis and treatment of abnormal vibration of vertical condenser pump motor towards ultra-supercritical 660mw turbo-generator set. IOP Conf. Ser. Earth Environ. Sci., 2019, 252, 032021.
[http://dx.doi.org/10.1088/1755-1315/252/3/032021]
[18]
Ganesh, P.; Rama Krishna, S. Diagnosis and resolution of vibration issues in vertical centrifugal pump. J. Fail. Anal. Prev., 2020, 20(3), 1019-1028.
[http://dx.doi.org/10.1007/s11668-020-00910-0]
[19]
Li, G; Sun, L; An, C; Gao, M Investigation on the changing characteristics of flow-induced noise in a centrifugal pump. Fluid Mech Mater Proc, 2021, 005, 017.
[http://dx.doi.org/10.32604/fdmp.2021.016507]
[20]
Zhang, S.; Tian, R.; Ding, K.; Chen, H.; Ma, Z. Numerical and experimental study in pressure pulsation and vibration of a two-stage centrifugal pump under cavitating condition. Mod. Phys. Lett. B, 2022, 36(1), 2150501.
[http://dx.doi.org/10.1142/S0217984921505011]
[21]
Yang, K. Dynamic analysis of multistage centrifugal pump rotor system with uncertain sliding bearing parameters; Chongqing University of Posts and Telecommunications, 2021.
[22]
Wang, H.; Zhou, X.; Dong, G.; Yang, J. Research on dynamic characteristics of condensate pump system in thermal power plant. Pump Technol, 2015, 1, 11-14.

Rights & Permissions Print Cite
© 2025 Bentham Science Publishers | Privacy Policy