[1]
P.P. Zeng, X. Qin, Y. Zhang, and C. Liang, "A design methodology for installing reactive compensation equipment in ultra high voltage AC transmission system based on a modified particle swarm optimisation method", In: Power Systems Computation Conference (PSCC), Wroclaw, Poland, 2014, pp. 1-6.
[2]
N.G. Hingorani, L. Gyugyi, and M. El-Hawary, Understanding FACTS: concepts and technology of flexible AC transmis-sion systems., vol. 1. IEEE press: New York, 2000.
[4]
K.R. Padiyar, FACTS controllers in power transmission and distributionNew Age International (P) Limited, Publishers, . 2007
[5]
Government of India, Ministry of Power., https://powermin.nic.in/en/content/overview-0 (Accessed October 19, 2018).
[6]
Government of India, Ministry of Power,, http://www.cea.nic.in/reports/monthly/installedcapacity/2018/installed_capacity-11.pdf (Accessed 07 December, 2018).
[7]
Q. Liu, J. Yu, H. Chen, and Y. Qin, Studies on series compensation of UHV transmission lineIEEE International Conference on Power System Technology, Hangzhou, China, 2010, pp. 1-5.
[10]
H. Fu, Z. Zhou, X. Wei, and F. Tao, "Study on the measurement of power-transmission-line parameters with induced voltage", In: China International Conference on Electricity Distribution, Nanjing, China, 2010, pp. 1-6.
[11]
S.V.N.J. Sundar, and M. Reshmi, "Utilization of controlled shunt reactor in a 400kV interconnected network", Int. J. Emerg. Electric Power Syst., vol. 2, no. 1, pp. 1-17, 2005.
[12]
S.J. Sundar, and G. Vaishnavi, Performance study of a continuously controlled shunt reactor for bus voltage management in EHV systemsInternational Conference on Power Systems Transients in Lyon, France, 2007, pp. 4-7.
[14]
S.V.N. Jitin Sundar, S.C. Bhareria, C.D. Khoday, A. Singhal, A.K. Tripathy, G.N. Alexandrov, M.M. Goswami, I.S. Jha, S. Sen, and V.K. Prasher, "Controlled shunt reactor- a member of FACTS family", In: 11th National Power System Conference, 2000, pp. 63-68.
[15]
S.V.N. Jitin Sundar, S.C. Bhareria, C.D. Khoday, A. Singhal, M.M. Goswami, A.R.C. Rao, J.S. Kuntia, M. Arunachalam, M.I. Khan, and G.N. Alexandrov, Design testing and commissioning of first 420kV 50 MVAR controlled shunt reactor in IndiaCIGRE Session Paris, 2002, pp. 14-120.
[16]
S.V.N. Jitin Sundar, R. Koul, M. Kumar, and Y.A. Raju, "Application of controlled shunt reactor for reactive power management of 1200 kV UHVAC transmission Line", In: GRIDTECH - 4th International Exhibition & Conference, New Delhi, India, 2013, pp. 16-22.
[17]
S. Bharti, and S.P. Dubey, "No-load performance study of 1200 kV Indian UHVAC transmission system", IET High Voltage, vol. 1, no. 3, pp. 130-137, 2016.
[21]
R.N. Nayak, M.C. Bhatnagar, B.N. and de Bhowmick, and R.K. Tyagi, "“1200 kV transmission system and status of development of substation equipment/ transmission line material in India”, Water Energ", Int., vol. 66, no. 4, pp. 70-77, 2009.
[22]
M.M. Goswami, and V.K. Lakhani, "Transformers for 1200 kV testing station at Bina", In: Fifteenth National Power Systems Conference IIT Bombay, India, 2008, pp. 504-507.
[23]
R.K. Tiwari, S.K. Gupta, R.K. Singh, G. Lalwani, and J.S. Kuntia, "Critical technical aspects during design, manufacturing and testing of India’s first 1200 kV UHVAC Transformer”", CIGRE.A2- 112, 2012,
[24]
T. Yokota, "Technical Requirements for Substations Exceeding
800 kV", CIGRE Working Group.B 3.22, 2009.,