Background: Bisphenol A (BPA) is considered one of the most common chemicals that could cause environmental endocrine disrupting. Therefore, there is an increasing demand for simple, rapid and sensitive methods for BPA detection that result from BPA leaching into foods and beverages from storage containers. Herein, a simple laccase electrochemical biosensor was developed for the determination of BPA based on Screen-Printed Carbon Electrode (SPCE) modified graphenegold/ chitosan. The synergic effect of graphene-gold/chitosan nanocomposite as electrode modifier greatly facilitates electron-transfer processes between the electrolyte and laccase enzyme, thus leads to a remarkably improved sensitivity for bisphenol A detection.

Methods: In this study, laccase enzyme is immobilized onto the Screen-Printed Carbon Electrode (SPCE) modified Graphene-Decorated Gold Nanoparticles (Gr-AuNPs) with Chitosan (Chit). The surface structure of nanocomposite was studied using different techniques including Field Emission Scanning Microscopy (FESEM), TRANSMISSION Electron Microscopy (TEM), Raman spectroscopy and Energy Dispersive X-ray (EDX). Meanwhile, the electrochemical performances of the modified electrodes were studied using Cyclic Voltammetry (CV) and Differential Pulse Voltammetry (DPV).

Result: The developed laccase biosensor offered excellent analytical performance for the detection of BPA with a sensitivity of 0.271 μA/μM and Limit of Detection (LOD) of 0.023 μM, respectively. Moreover, the constructed biosensor showed good reproducibility, selectivity and stability towards BPA. The sensor has been used to detect BPA in a different type of commercial plastic products as a real sample and satisfactory result was obtained when compared with the HPLC method.

Conclusion: The proposed electrochemical laccase biosensor exhibits good result which is considered as a promising candidate for a simple, rapid and sensitive method especially in the resource- limited condition.

Keywords: Bisphenol A, electrochemical biosensor, graphene-gold nanocomposite, laccase, Screen-Printed Carbon Electrode (SPCE), synergic effect.

Graphical Abstract

[1]
Zhan, T.; Song, Y.; Tan, Z.; Hou, W. Electrochemical bisphenol A sensor based on exfoliated Ni2Al-layered double hydroxide nanosheets modified electrode. Sens. Actuators B Chem., 2017, 238, 962-971.
[http://dx.doi.org/10.1016/j.snb.2016.07.151]
[2]
Yun, Y. Effect of Thermal Annealing on the Electrochemical Capacitive Performance of Reduced Microcrystalline Graphene Oxide. Int. J. Electrochem. Sci., 2016, 11, 2778-2789.
[http://dx.doi.org/10.20964/110402778]
[3]
Ghazali, F.M.; Johari, W.L.W. The occurrence and analysis of bisphenol A (BPA) in environmental samples – a review. J. Biochem. Microbiol. Biotechnol., 2015, 3, 30-38.
[4]
Zhao, W.R.; Kang, T.F.; Lu, L.P.; Shen, F.X.; Cheng, S.Y. A novel electrochemical sensor based on gold nanoparticles and molecularly imprinted polymer with binary functional monomers for sensitive detection of bisphenol A. J. Electroanal. Chem. (Lausanne Switz.), 2017, 786, 102-111.
[http://dx.doi.org/10.1016/j.jelechem.2017.01.003]
[5]
Niu, X.; Yang, W.; Wang, G.; Ren, J. Guo, H; Gao J. A novel electrochemical sensor of bisphenol A based on stacked graphene nanofibers/gold nanoparticles composite modified glassy carbon electrode. Electrochim. Acta, 2013, 98, 167-175.
[http://dx.doi.org/10.1016/j.electacta.2013.03.064]
[6]
Ragavan, K.V.; Rastogi, N.K.; Thakur, M.S. Sensors and biosensors for analysis of bisphenol-A. TrAC- Trends Analyt. Chem., 2013, 52, 248-260.
[http://dx.doi.org/10.1016/j.trac.2013.09.006]
[7]
Giulivo, M.; Lopez de Alda, M.; Capri, E.; Barceló, D.; Barcelo, D. Human exposure to endocrine disrupting compounds: Their role in reproductive systems, metabolic syndrome and breast cancer. A review. Environ. Res., 2016, 151, 251-264.
[http://dx.doi.org/10.1016/j.envres.2016.07.011] [PMID: 27504873]
[8]
Völkel, W.; Kiranoglu, M.; Fromme, H. Determination of free and total bisphenol A in human urine to assess daily uptake as a basis for a valid risk assessment. Toxicol. Lett., 2008, 179(3), 155-162.
[http://dx.doi.org/10.1016/j.toxlet.2008.05.002] [PMID: 18579321]
[9]
Kouidhi, AMM; Thannimalay, W, L; Soon, CS Occupational exposure to bisphenol A (BPA) in a plastic injection molding factory in Malaysia. Int. J. Occup. Med. Environ. Health, 2017, 646, 10743-750.
[10]
Cunha, S.C.; Fernandes, J.O. Determination of bisphenol A and bisphenol B in canned seafood combining QuEChERS extraction with dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry. Food Control, 2013, 33, 549-555.
[http://dx.doi.org/10.1016/j.foodcont.2013.03.028]
[11]
Zimmers, S.M.; Browne, E.P.; O’Keefe, P.W.; Anderton, D.L.; Kramer, L.; Reckhow, D.A.; Arcaro, K.F. Determination of free Bisphenol A (BPA) concentrations in breast milk of U.S. women using a sensitive LC/MS/MS method. Chemosphere, 2014, 104, 237-243.
[http://dx.doi.org/10.1016/j.chemosphere.2013.12.085] [PMID: 24507723]
[12]
Fontana, A.R.; Muñoz de Toro, M.; Altamirano, J.C. One-step derivatization and preconcentration microextraction technique for determination of bisphenol A in beverage samples by gas chromatography-mass spectrometry. J. Agric. Food Chem., 2011, 59(8), 3559-3565.
[http://dx.doi.org/10.1021/jf104622x] [PMID: 21381775]
[13]
Montereali, M.R.; Della Seta, L.; Vastarella, W.; Pilloton, R. A disposable Laccase–Tyrosinase based biosensor for amperometric detection of phenolic compounds in must and wine. J. Mol. Catal., B Enzym., 2010, 64, 189-194.
[http://dx.doi.org/10.1016/j.molcatb.2009.07.014]
[14]
Reddaiah, K.; Reddy, T.M. Electrochemical biosensor based on silica sol-gel entrapment of horseradish peroxidase onto the carbon paste electrode toward the determination of 2-aminophenol in non-aqueous solvents: A voltammetric study. J. Mol. Liq., 2014, 196, 77-85.
[http://dx.doi.org/10.1016/j.molliq.2014.03.023]
[15]
Alam, M.K.; Rahman, M.M.; Abbas, M.; Ramulu, S.; Asiri, A.M.; Kim, D. Ultra-sensitive 2-nitrophenol detection based on reduced graphene oxide/ZnO nanocomposites. J. Electroanal. Chem. (Lausanne Switz.), 2017, 788, 66-73.
[http://dx.doi.org/10.1016/j.jelechem.2017.02.004]
[16]
Ozoner, S.K.; Erhan, E.; Yilmaz, F. Enzyme-Based phenol biosensors. Environ. Biosens., 2007, 15, 356.
[17]
Romero-Arcos, M.; Guadalupe Garnica-Romo, M. Martínez-Flores, H.E. Electrochemical study and characterization of an amperometric biosensor based on the immobilization of laccase in a nanostructure of tio2 synthesized by the sol-gel method. Materials (Basel), 2016, 9, 543.
[http://dx.doi.org/10.3390/ma9070543]
[18]
Rodriguez-delgado, M.M.; Aleman-nava, G.S.; Rodriguez-delgado, J.M.; Dieck-assad, G.; Martínez-chapa, S.O.; Barcelo, D. Laccase-based biosensors for detection of phenolic compoundsTrAC. Trends Analyt. Chem., 2015, 74, 21-45.
[http://dx.doi.org/10.1016/j.trac.2015.05.008]
[19]
Sumitra, D; L, Rene; C, Yamuna R. S. R. Enzyme immobilization: an overview on techniques and support materials 3 Biotech, 2013, 3(1), 1-9.
[20]
van de Velde, F.; Lourenço, N.D.; Pinheiro, H.M.; Bakker, M. Carrageenan: a food-grade and biocompatible support for immobilisation techniques. Adv. Synth. Catal., 2002, 344, 815-835.
[http://dx.doi.org/10.1002/1615-4169(200209)344:8<815:AID-ADSC815>3.0.CO;2-H]
[21]
Zhu, C.; Yang, G.; Li, H.; Du, D.; Lin, Y. Electrochemical sensors and biosensors based on nanomaterials and nanostructures. Anal. Chem., 2015, 87(1), 230-249.
[http://dx.doi.org/10.1021/ac5039863] [PMID: 25354297]
[22]
Krishnan, S.K.; Singh, E.; Singh, P.; Meyyappan, M.; Nalwa, H.S. A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors. RSC Advances, 2019, 9, 8778-8881.
[http://dx.doi.org/10.1039/C8RA09577A]
[23]
Pan, D.; Gu, Y.; Lan, H.; Sun, Y.; Gao, H. Functional graphene-gold nano-composite fabricated electrochemical biosensor for direct and rapid detection of bisphenol A. Anal. Chim. Acta, 2015, 853, 297-302.
[http://dx.doi.org/10.1016/j.aca.2014.11.004] [PMID: 25467472]
[24]
Zhou, L.; Wang, J.; Li, D.; Li, Y. An electrochemical aptasensor based on gold nanoparticles dotted graphene modified glassy carbon electrode for label-free detection of bisphenol A in milk samples. Food Chem., 2014, 162(162), 34-40.
[http://dx.doi.org/10.1016/j.foodchem.2014.04.058] [PMID: 24874354]
[25]
Fartas, F; Abdullah, J; Yusof, N; Sulaiman, Y; Saiman, M. Biosensor Based on Tyrosinase Immobilized on Graphene-Decorated Gold Nanoparticle/Chitosan for Phenolic Detection in AqueousSensors., 2017, 17, 1132.
[26]
Geetha Bai, R; Muthoosamy, K; Zhou, M; Ashokkumar, M; Huang, N.M,; Manickam, S. Sonochemical and sustainable synthesis of graphene-gold (G-Au) nanocomposites for enzymeless and selective electrochemical detection of nitric oxide.S,,
[27]
Bustos-Ramirez, K.; Martinez-Hernandez, A.L.; Martinnez-Barrera, G.; de Icaza, M.; Castano, V.M.; Velasco-Santos, C. Velasco- Santos, Covalently Bonded Chitosan on Graphene Oxide via Redox ReactionMaterials (Basel)., 2013, 6, 911-926.a..
[28]
Kumar, A.S.K.; Jiang, S.J. Chitosan-functionalized graphene oxide: A novel adsorbent an efficient adsorption of arsenic from aqueous solution. J. Environ. Chem. Eng., 2016, 4, 1698-1713.
[http://dx.doi.org/10.1016/j.jece.2016.02.035]
[29]
Li, C.; Zhou, Y. Zhu,X; Ye, B;Xu.M, Construction of a Sensitive Bisphenol A Electrochemical Sensor based on Metal-organicFramework/Graphene Composites. Int. J. Electrochem. Sci., 2018, 13, 4855-4867.
[http://dx.doi.org/10.20964/2018.05.52]
[30]
Wei, T.; Huang, X.; Zeng, Q.; Wang, L. Simultaneous electrochemical determination of nitrophenol isomers with the polyfurfural film modified glassy carbon electrode. J. Electroanal. Chem. (Lausanne Switz.), 2015, 743, 105-111.
[http://dx.doi.org/10.1016/j.jelechem.2015.02.031]
[31]
Hua, Z.; Qin, Q.; Bai, X.; Wang, C.; Huang, X. Cyclodextrin inclusion complex as the immobilization matrix for laccase in the fabrication of a biosensor for dopamine determination. Sens. Actuators B Chem., 2015, 220, 1169-1177.
[http://dx.doi.org/10.1016/j.snb.2015.06.108]
[32]
Frasconi, M; Favero, G; Boer, H; Koivula, A; Mazzei, F Kinetic and biochemical properties of high and low redox potential laccases from fungal and plant origin Biochimica Proteins Proteomics., 2010, 1804, 899-908.l.
[33]
Zhan, T.; Song, Y.; Li, X.; Hou, W. Electrochemical sensor for bisphenol A based on ionic liquid functionalized Zn-Al layered double hydroxide modified electrode. Mater. Sci. Eng. C, 2016, 64, 354-361.
[http://dx.doi.org/10.1016/j.msec.2016.03.093] [PMID: 27127064]
[34]
Yang, Y.; Zhang, H. Huang,C; Jia,N. MWCNTs-PEI composites-based electrochemical sensor for sensitive detection of bisphenol. Sens. Actuators B Chem., 2016, 235, 408-413.
[http://dx.doi.org/10.1016/j.snb.2016.05.105]
[35]
Zhang, Y.; Cheng, Y.; Zhou, Y.; Li, B.; Gu, W.; Shi, X.; Xian, Y. Electrochemical sensor for bisphenol A based on magnetic nanoparticles decorated reduced graphene oxide. Talanta, 2013, 107, 211-218.
[http://dx.doi.org/10.1016/j.talanta.2013.01.012] [PMID: 23598214]
[36]
Oliveira, T.M.; Barroso, M.F.; Morais, S.; Araújo, M.; Freire, C.; de Lima-Neto, P.; Correia, A.N.; Oliveira, M.B.; Delerue-Matos, C. Sensitive bi-enzymatic biosensor based on polyphenoloxidases-gold nanoparticles-chitosan hybrid film-graphene doped carbon paste electrode for carbamates detection. Bioelectrochemistry, 2014, 98, 20-29.
[http://dx.doi.org/10.1016/j.bioelechem.2014.02.003] [PMID: 24642204]
[37]
Portaccio, M.; Di Tuoroa, D.; Arduini, F.; Mosconec, D.; Cammarotaa, M. Laccase biosensor based on screen-printed electrode modified with thionine–carbon black nanocomposite, for Bisphenol A detection. Electrochim. Acta, 2013, 109, 340-347.
[http://dx.doi.org/10.1016/j.electacta.2013.07.129]
[38]
Xu, X.; Zheng, Q.; Song, L.; Bai, G.; Cao, X.D.; Liu, S.; You, C. Polydopamine induced in-situ growth of Au nanoparticles on reduced graphene oxide as an efficient biosensing platform for ultrasensitive detection of bisphenol. Electrochim. Acta, 2017, 242
[http://dx.doi.org/10.1016/j.electacta.2017.05.007]
[39]
Wu, L.; Deng, D.; Jin, J.; Lu, X.; Chen, J. Nanographene-based tyrosinase biosensor for rapid detection of bisphenol A. Biosens. Bioelectron., 2012, 35(1), 193-199.
[http://dx.doi.org/10.1016/j.bios.2012.02.045] [PMID: 22445847]
[40]
Yin, H.; Zhou, Y.; Xu, J.; Ai, S.; Cui, L.; Zhu, L. Amperometric biosensor based on tyrosinase immobilized onto multiwalled carbon nanotubes-cobalt phthalocyanine-silk fibroin film and its application to determine bisphenol A. Anal. Chim. Acta, 2010, 659(1-2), 144-150.
[http://dx.doi.org/10.1016/j.aca.2009.11.051] [PMID: 20103117]
[41]
Wang, X.; Lu, X.; Wu, L.; Chen, J. 3D metal-organic framework as highly efficient biosensing platform for ultrasensitive and rapid detection of bisphenol A. Biosens. Bioelectron., 2015, 65, 295-301.
[http://dx.doi.org/10.1016/j.bios.2014.10.010] [PMID: 25461172]

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy