[1]
P. Zhang, Y. Du, T.G. Habetler, and B. Lu, "A survey of condition monitoring and protection methods for medium-voltage induction motors", IEEE Trans. Ind. Appl., vol. 47, pp. 34-46, 2011.
[2]
S. Bindu, and V.V. Thomas, "Diagnoses of internal faults of three
phase squirrel cage induction motor - A review, In:", Proc. 2014
Int. Conf. Adv. Energy Convers. Technol. - Intell. Energy Manag.
Technol. Challenges, ICAECT. pp. 48-54. 2014.
[3]
M. Sahraoui, S. Zouzou, A. Ghoggal, and S. Guedidi, "A new method
to detect inter-turn short-circuit in induction motors", 19th Int. Conf.
Electr. Mach. ICEM. 2010.
[4]
S. Das, P. Purkait, and S. Chakravorti, "Separating induction motor current signature for stator winding faults from that due to supply voltage unbalances", 1st Int Conf Power Energy NERIST, ICPEN- Proc, 2012 0-5
[5]
A. Lebaroud, and A. Medoued, "Online computational tools dedicated to the detection of induction machine faults", Int. J. Electr. Power Energy Syst., vol. 44, pp. 752-757, 2013.
[6]
R. Sharifi, and M. Ebrahimi, "Detection of stator winding faults in induction motors using three-phase current monitoring", ISA Trans., vol. 50, pp. 14-20, 2011.
[7]
M.B.K. Bouzid, and G. Champenois, "New expressions of symmetrical components of the induction motor under stator faults", IEEE Trans. Ind. Electron., vol. 60, pp. 4093-4102, 2013.
[8]
M. Bouzid, and G. Champenois, "An efficient, simplified multiple-coupled circuit model of the induction motor aimed to simulate different types of stator faults", Math. Comput. Simul., vol. 90, pp. 98-115, 2013.
[9]
S. Chattopadhyay, S. Karmakar, M. Mitra, and S. Sengupta, "Symmetrical components and current concordia based assessment of single phasing of an induction motor by feature pattern extraction method and radar analysis", Int. J. Electr. Power Energy Syst., vol. 37, pp. 43-49, 2012.
[10]
H. Liangliang, S. Yuguang, and Q. Ami, "Analysis on the negative
sequence impedance directional protection for stator internal fault
of turbo generator, In:", Int. Conf. Electr. Mach. Syst. Incheon,
South Korea, pp. 1421-1424, 2010.
[11]
Y. Zhao, Y. Chen, L. Wang, A.U. Rehman, Y. Cheng, Y. Zhao, B. Han, and T. Tanaka, "Experimental research and feature extraction
on stator inter-turn short circuit fault in DFIG, In:", Proc. 2016
IEEE Int. Conf. Dielectr. ICD. Montpellier, France, vol. 1, 2016,
pp. 510-513.
[12]
C. Bouchareb, and M.S. Nait-Said, "PMSM model with phase-to-phase short-circuit and diagnosis by ESA and EPVA", Adv. Electr. Electron. Eng., vol. 14, pp. 522-530, 2016.
[13]
S. Bachir, S. Tnani, J.C. Trigeassou, and G. Champenois, "Diagnosis by parameter estimation of stator and rotor faults occurring in induction machines", IEEE Trans. Ind. Electron., vol. 53, pp. 963-973, 2006.
[14]
I.B.A. Bazine, S. Tnani, T. Poinot, G. Champenois, and K. Jelassi, "Online
detection of stator and rotor faults occurring in induction
machine diagnosis by parameters estimation, In", SDEMPED 2011
- 8th IEEE Symp Diagnostics Electr Mach Power Electron Drives. Bologna, Italy, 2011, pp. 105-112.
[15]
M. Khov, J. Regnier, and J. Faucher, "Detection of turn short-circuit
faults in stator of PMSM by on-line parameter estimation, In", SPEEDAM 2008 - Int Symp Power Electron Electr Drives, Autom
Motion. Ischia, Italy, 2008, pp. 161-166.
[16]
J. Lee, S. Moon, H. Jeong, and S.W. Kim, "Robust diagnosis method
based on parameter estimation for an interturn short-circuit fault in
multipole PMSM under high-speed operation", Sensors
(Switzerland). vol. 15, pp. 29452-29466, 2015.
[17]
F. Duan, and R. Živanović, "Induction motor stator fault detection by a condition monitoring scheme based on parameter estimation algorithms", Electr. Power Components. Syst., vol. 44, pp. 1138-1148, 2016.
[18]
M. Nentwig, and P. Mercorelli, "Throttle valve control using an inverse
local linear model tree based on a fuzzy neural network", 7th IEEE
Int Conf Cybern Intell Syst. London, UK, 2008.
[19]
P. Mercorelli, and P. Terwiesch, "A black box identification in frequency domain", Eur. Trans. Electr. Power, vol. 13, pp. 29-40, 2003.
[20]
M. Wolkiewicz, and C.T. Kowalski, Incipient stator fault detector based on neural networks end symmetrical components analysis for induction motor drives., Sel. Issues Electr. Eng. Electron. WZEE, 2016.
[21]
L.S. Bin, R.M. Tallam, and T.G. Habetler, "A robust, on-line turn-fault detection technique for induction machines based on monitoring the sequence component impedance matrix", IEEE Trans. Power Electron., vol. 18, pp. 865-872, 2003.
[22]
F. Duan, and R. Živanović, "Condition monitoring of an induction motor stator windings via global optimization based on the hyperbolic cross points", IEEE Trans. Ind. Electron., vol. 62, pp. 1826-1834, 2015.
[23]
M. Eftekhari, M. Moallem, S. Member, and S. Sadri, "Online detection of induction motor’s stator winding short-circuit faults", IEEE Syst. J., vol. 8, pp. 1272-1282, 2014.
[24]
C.L. Fortescue, "Method of symmetrical co-ordinates applied to the solution of polyphase networks", Trans. Am. Inst. Electr. Eng., vol. XXXVII, pp. 1027-1140, 1918.
[25]
M. Bouzid, and G. Champenois, "A novel reliable indicator of
stator windings fault in induction motor extracted from the
symmetrical components, In", Proc - ISIE IEEE Int. Symp. Ind.
Electron. Gdansk, Poland, pp. 489-95, 2011.