Abstract
Background: Glucose sensors have been extensively researched in patent studies and manufactured a tool for clinical diabetes diagnosis. Although some kinds of electrochemical enzymatic glucose sensors have been commercially successful, there is still room for improvement, in selectivity and reliability of these sensors. Because of the intrinsic disadvantages of enzymes, such as high fabrication cost and poor stability, non-enzymatic glucose sensors have recently been promoted as next generation diagnostic tool due to their relatively low cost, high stability, prompt response, and accuracy.
Objective: In this research, a novel free standing and binder free non-enzymatic electrochemical sensor was manufactured using in situ grown copper (Cu) and cobalt (Co) on a silicon (Si) substrate.
Methods: Scanning High-Energy Electron Diffraction (SHEED) and Edward deposition methods were used to synthesise the sensors.
Results: Morphological observations showed that Cu and Co homogeneously formed nanorod-like shapes over the Si substrate. The elemental composition and structure of the prepared sensors were identified by Reflection High-Energy Electron Diffraction (RHEED). In terms of electrochemical properties, for the enzyme-free glucose sensor, voltammograms showed that the peak currents increased when the glucose solution was injected into the electrolytic cell. The electrical relation of voltage versus current was linear, as shown in the experimental data. Another effective parameter changed the magnetic field; and the linear behaviour of the electrical resistance of Co remained unaltered.
Conclusion: In the optimum annealing temperature, where the magnetic field increased, the properties of the samples remained constant. In other words, in the selected annealing temperature, resistance and stability of the layers increased in a significant manner.
Keywords: Copper, cobalt, nanostructure, enzyme-free, sensor, nanorod arrays.
Graphical Abstract
Recent Patents on Biotechnology
Title:High-Performance Enzyme-Free Glucose Sensor with Co-Cu Nanorod Arrays on Si Substrates
Volume: 12 Issue: 2
Author(s): Haji Shirinzadeh, Abolfazl Yazdanpanah, Dimitrios Karponis, Behzad Aghabarari, Mohammad Tahmasbi, Alexander Seifalian*Masoud Mozafari*
Affiliation:
- Nanotechnology and Regenerative Medicine Commercialisation Centre (Ltd), The London BioScience Innovation Centre, London,United Kingdom
- Bioengineering Research Group, Nanotechnology and Advanced Materials Department, Materials and Energy Research Centre (MERC), Tehran,Iran
Keywords: Copper, cobalt, nanostructure, enzyme-free, sensor, nanorod arrays.
Abstract: Background: Glucose sensors have been extensively researched in patent studies and manufactured a tool for clinical diabetes diagnosis. Although some kinds of electrochemical enzymatic glucose sensors have been commercially successful, there is still room for improvement, in selectivity and reliability of these sensors. Because of the intrinsic disadvantages of enzymes, such as high fabrication cost and poor stability, non-enzymatic glucose sensors have recently been promoted as next generation diagnostic tool due to their relatively low cost, high stability, prompt response, and accuracy.
Objective: In this research, a novel free standing and binder free non-enzymatic electrochemical sensor was manufactured using in situ grown copper (Cu) and cobalt (Co) on a silicon (Si) substrate.
Methods: Scanning High-Energy Electron Diffraction (SHEED) and Edward deposition methods were used to synthesise the sensors.
Results: Morphological observations showed that Cu and Co homogeneously formed nanorod-like shapes over the Si substrate. The elemental composition and structure of the prepared sensors were identified by Reflection High-Energy Electron Diffraction (RHEED). In terms of electrochemical properties, for the enzyme-free glucose sensor, voltammograms showed that the peak currents increased when the glucose solution was injected into the electrolytic cell. The electrical relation of voltage versus current was linear, as shown in the experimental data. Another effective parameter changed the magnetic field; and the linear behaviour of the electrical resistance of Co remained unaltered.
Conclusion: In the optimum annealing temperature, where the magnetic field increased, the properties of the samples remained constant. In other words, in the selected annealing temperature, resistance and stability of the layers increased in a significant manner.
Export Options
About this article
Cite this article as:
Shirinzadeh Haji , Yazdanpanah Abolfazl , Karponis Dimitrios , Aghabarari Behzad , Tahmasbi Mohammad , Seifalian Alexander*, Mozafari Masoud *, High-Performance Enzyme-Free Glucose Sensor with Co-Cu Nanorod Arrays on Si Substrates, Recent Patents on Biotechnology 2018; 12 (2) . https://dx.doi.org/10.2174/1872208311666170713150220
DOI https://dx.doi.org/10.2174/1872208311666170713150220 |
Print ISSN 1872-2083 |
Publisher Name Bentham Science Publisher |
Online ISSN 2212-4012 |

- Author Guidelines
- Bentham Author Support Services (BASS)
- Graphical Abstracts
- Fabricating and Stating False Information
- Research Misconduct
- Post Publication Discussions and Corrections
- Publishing Ethics and Rectitude
- Increase Visibility of Your Article
- Archiving Policies
- Peer Review Workflow
- Order Your Article Before Print
- Promote Your Article
- Manuscript Transfer Facility
- Editorial Policies
- Allegations from Whistleblowers