Generic placeholder image

Current Pharmaceutical Analysis

Editor-in-Chief

ISSN (Print): 1573-4129
ISSN (Online): 1875-676X

Research Article

Ephedrine Analysis in Real Urine Sample via Solvent Bar Microextraction Technique Coupled with HPLC-UV and Chemometrics

Author(s): Persia Behbahani, Mahnaz Qomi*, Nahid Ghasemi and Kambiz Tahvildari

Volume 15, Issue 1, 2019

Page: [24 - 31] Pages: 8

DOI: 10.2174/1573412913666170613093620

Price: $65

Abstract

Background: Ephedrine, an alpha/beta-adrenergic agonist, is one of the most common doping agents not only among athletes but also the ordinary people, therefore its detection at low trace levels with a sensitive and cost effective method has become a priority to investigate many analytical methods.

Objective: In this work, solvent bar microextraction followed by high-performance liquid chromatography (HPLC-UV) was used for extraction and determination of ephedrine at low trace levels from urine samples at optimum condition.

Methods: In this study, a designed experiment was carried out using solvent bar microextraction technique, which has been proved to be a green method. This method requires three phases consisting of a donor phase with an alkaline pH, an acceptor phase with an acidic pH, and organic solvent to impregnate the pores of the hollow fiber. The obtained results were used for estimating the optimum ranges for each parameter, analyzing the effect of different parameters, simultaneously.

Results: Under optimized circumstances, the preconcentration factor was 129. The calibration curves represented good linearity for urine sample with coefficient estimations higher than 0.9991. The limit of detection and quantitation for ephedrine were 16.7 µg L-1 and 50 µg L-1, respectively. The relative standard deviations of analysis were 3.5% within a day (n=3) and 4.1% between days (n=9).

Conclusion: According to the results and previous studies, it can be concluded that the preconcentration factor for ephedrine was the best result ever reported considering selectivity and cost-effectiveness.

Keywords: Ephedrine, solvent bar microextraction, high-performance liquid chromatography, hollow fiber, chemometric method, Design of Experiment (DOE).

Graphical Abstract

[1]
Sjöqvist, F.; Garle, M.; Rane, A. Use of doping agents, particularly anabolic steroids, in sports and society. Lancet, 2008, 371(9627), 1872-1882.
[2]
Dhar, R.; Stout, C.W.; Link, M.S.; Homoud, M.K.; Weinstock, J.; Estes, N.M. In: Cardiovascular toxicities of performanceenhancing substances in sports,, , Mayo Clinic Proceedings, Elsevier: 2005; pp 1307-1315..
[3]
Montisci, M.; El Mazloum, R.; Cecchetto, G.; Terranova, C.; Ferrara, S.D.; Thiene, G.; Basso, C. Anabolic androgenic steroids abuse and cardiac death in athletes: morphological and toxicological findings in four fatal cases. Forensic Sci. Int., 2012, 217(1), e13-e18.
[4]
Dhar, R.; Stout, C.W.; Link, M.S.; Homoud, M.K.; Weinstock, J.; Estes, N.M. In: Cardiovascular toxicities of performanceenhancing substances in sports,, , Mayo Clinic Proceedings, Elsevier: 2005; pp 1307-1315.
[5]
Thiblin, I.; Mobini-Far, H.; Frisk, M. Sudden unexpected death in a female fitness athlete, with a possible connection to the use of anabolic androgenic steroids (AAS) and ephedrine. Forensic Sci. Int., 2009, 184(1), e7-e11.
[6]
Taghvimi, A.; Hamishehkar, H. Carbon coated magnetic nanoparticles as a novel magnetic solid phase extraction adsorbent for simultaneous extraction of methamphetamine and ephedrine from urine samples. J. Chromatogr. B., 2017, 1041, 113-119.
[7]
Kojima, A.; Nishitani, Y.; Sato, M.; Kageyama, S.; Dohi, M.; Okano, M. Comparison of urine analysis and dried blood spot analysis for the detection of ephedrine and methylephedrine in doping control. Drug Testi. Anal., 2015, 8(2), 189-198.
[8]
Miraee, S.N.; Qomi, M.; Shamshiri, F.; Raoufi, P. Hollow-Fiber liquid-phase microextraction followed by high performance liquid chromatography for the determination of trace amounts of methylphenidate hydrochloride in biological fluids. Biomed. Pharmacol. J., 2014, 7(2), 715-725.
[9]
Piroozi, F.; Ghasemi, E.; Qomi, M.; Rezaee, R.; Hashemian, F. Hollow fiber liquid phase microextraction combined with high performance liquid chromatography for preconcentration and determination of cabergoline in biological samples. J. Liq. Chromatogr. Related. Technol., 2014, 37(5), 760-771.
[10]
Boloori, V.; Qomi, M.; Piroozi, F.; Raofie, F. Development of a simple and efficient method for preconcentration and determination of trace levels of fexofenadine in plasma and urine samples. J. Applied Chem. Res., 2016, 10(3), 7-14.
[11]
A, Afshari. R.; Qomi, M. A novel application of three phase Hollow Fiber Based Liquid Phase Microextraction (HF-LPME) for the HPLC determination of tamsulosin from biological fluids. Curr. Pharmaceutic. Anal., 2016, 12(3), 258-265.
[12]
Emad, Z.S. Three-phase hollow fiber liquid-phase micro extraction for determination and analysis of terazosin in biological fluids via high performance liquid chromatography at trace levels. Current. Anal. Chem., 2016, 12(5)
[13]
Ashrafzadeh, T.; Qomi, M. Preconcentration and determination of ephedrine using hollow fiber microextraction coupled with HPLC. Curr. Anal. Chem., 2016, 12(6), 594-601.
[14]
Akhondi, E.; Zamani, F.; Law, A.W.; Krantz, W.B.; Fane, A.G.; Chew, J.W. Influence of backwashing on the pore size of hollow fiber ultrafiltration membranes. J. Membrane. Sci., 2017, 521, 33-42.
[15]
Akramipour, R.; Fattahi, N.; Pirsaheb, M.; Gheini, S. Combination of counter current salting-out homogenous liquid–liquid extraction and dispersive liquid–liquid microextraction as a novel microextraction of drugs in urine samples. J. Chromatogr. B., 2016, 1012, 162-168.
[16]
Ansari, S.; Karimi, M. Recent progress, challenges and trends in trace determination of drug analysis using molecularly imprinted solid-phase microextraction technology. Talanta, 2017, 164, 612-625.
[17]
Solmaz, F.; Mahnaz, Q.; Marjan, G. Preconcentration and determination of cabergoline using the green practical solvent bar liquid phase microextraction technique in biological fluids. Curr. Pharmaceut. Anal., 2017, 13, 1-1.
[18]
Deventer, K.; Pozo, O.; Verstraete, A.; Van Eenoo, P. Dilute-and-shoot-liquid chromatography-mass spectrometry for urine analysis in doping control and analytical toxicology. TrAC. Trends Anal. Chem., 2014, 55, 1-13.
[19]
Du, W.; Zhao, G.; Fu, Q.; Sun, M.; Zhou, H.; Chang, C. Combined microextraction by packed sorbent and high-performance liquid chromatography–ultraviolet detection for rapid analysis of ractopamine in porcine muscle and urine samples. Food Chem., 2014, 145, 789-795.
[20]
Fang, L-L.; Wang, P.; Wen, X-l.; Guo, X.; Yu, J.; Guo, X-J. Layer-by-layer self-assembly of gold nanoparticles/thiols β-cyclodextrin coating as the stationary phase for enhanced chiral differentiation in open tubular capillary electrochromatography. Talanta, 2017, 167, 158-165.
[21]
Neukamm, M.A.; Bahrami, A.; Auwärter, V.; Mehne, F.M.; Höss, E. Evaluation of KIMS immunoassays on a cobas c 501 analyzer for drugs of abuse and ethyl glucuronide testing in urine for forensic abstinence control. Drug Test. Anal., 2017, 9(8), 1217-12236.
[22]
Nguyen, T.A.H.; Pham, T.N.M.; Ta, T.T.; Nguyen, X.T.; Nguyen, T.L.; Le, T.H.H.; Koenka, I.J.; Sáiz, J.; Hauser, P.C.; Mai, T.D. Screening determination of four amphetamine-type drugs in street-grade illegal tablets and urine samples by portable capillary electrophoresis with contactless conductivity detection. Sci. Justice, 2015, 55(6), 481-486.
[23]
Nováková, L.; Rentsch, M.; Perrenoud, A.G-G.; Nicoli, R.; Saugy, M.; Veuthey, J.L.; Guillarme, D. Ultra high performance supercritical fluid chromatography coupled with tandem mass spectrometry for screening of doping agents. II: Analysis of biological samples. Analyt. Chimica. Acta, 2015, 853, 647-659.

© 2024 Bentham Science Publishers | Privacy Policy