Generic placeholder image

Current Pharmaceutical Analysis

Editor-in-Chief

ISSN (Print): 1573-4129
ISSN (Online): 1875-676X

Research Article

Evaluation of the Quality of Water Samples Purified by Compounding Pharmacies in Brazil

Author(s): Lucas Prosperi Ferreira, Marcus Vinicius Martins Rubatino*, Magali Benjamin de Araújo and Rudy Bonfilio

Volume 20, Issue 1, 2024

Published on: 08 January, 2024

Page: [12 - 21] Pages: 10

DOI: 10.2174/0115734129247763231224172204

Price: $65

Abstract

Background: Highly purified water is essential for the production of pharmaceuticals, directly impacting the quality and safety of the final product.

Methods: In this work, we studied the physicochemical and microbiological quality of 1477 purified water samples from 25 compounding pharmacies in Southeast Brazil. To the best of our knowledge, this is the most comprehensive study on the quality of water purified in Brazil. It was observed that 47.7% of the samples were purified by reverse osmosis, 39.9% by distillation and 12.4% by deionization. Of the total, 10.63% presented one or more non-compliances. Amongst the three purification processes, the amount of non-compliance was found to be 8.9% for reverse osmosis, 10.9% for deionization, and 12.4% for distillation.

Results: It was therefore concluded that reverse osmosis is advantageous. However, even the advantageous reverse osmosis process showed contamination by viable bacteria, total and faecal coliforms/ E. coli, and Pseudomonas aeruginosa.

Conclusion: Quantitative data showed that all purification processes significantly reduced the conductivity and pH values of the input water. However, conductivity values above the limits and several other non-compliances were found after purification by all processes, which points to the need for additional studies on improvements in purification processes adopted by compounding pharmacies in Brazil.

[2]
Belkacem, M.; Bensadok, K.; Refes, A.; Charvier, P.M.; Nezzal, G. Water produce for pharmaceutical industry: Role of reverse osmosis stage. Desalination, 2008, 221(1-3), 298-302.
[http://dx.doi.org/10.1016/j.desal.2007.01.086]
[3]
Mannepalli, K.R.; Deshpande, B.; Mundeja, P. Hot water sanitization and its impact on microbial biofilm causing bacteria pseudomonas aeruginosa and pseudomonas putida. Asian J. Microbiol. Biotechnol. Environ. Sci., 2022, 187-191, 187-191.
[http://dx.doi.org/10.53550/AJMBES.2022.v24i01.029]
[4]
Moura, J.P.; Monteiro, G.S.; Silva, J.N.; Pinto, F.A.; França, K.P. Applications of the Reverse Osmosis Process for the Use of Brackish Water from the Northeastern Semi-Arid Region; Águas Subterrâneas, 2008.
[5]
USP 42 - NF 37 The United States pharmacopeia and national formulary 2019 main edition plus supplements 1 and 2, 1. Auflage. In: Deutscher Apotheker Verlag; Stuttgart; , 2018.
[6]
Costa, M.A.B.; Brandão, A.L.T.; Pinto, J.C.; Nele, M. Application of HACCP for development of quality risk management in a water purification system. Braz. J. Pharm. Sci., 2022, 58, e191051.
[http://dx.doi.org/10.1590/s2175-97902022e191051]
[7]
De Matos, D.T.; De Carvalho, F.S.; Dos Santos, F.M. Electrical Conductivity and Total Organic Carbon Analysis of Water in Brazilian Industrial Pharmaceutical Formulations., 2022, 13(1)
[http://dx.doi.org/10.7324/JAPS.2023.130118]
[8]
Farjami, A.; Eradati, S.; Hamishehkar, H.; Siahi-Shadbad, M.; LotfiPour, F. Effect of peracetic acid–ultraviolet combination treatment on microbial and endotoxin levels in a pharmaceutical water system. J. Water Sanit. Hyg. Dev., 2022, 12(10), 698-710.
[http://dx.doi.org/10.2166/washdev.2022.071]
[9]
Brazil. The brazilian pharmacopeia. 6th edition. 2019. Available from: https://www.anvisa.gov.br/anvisa/pt-br/assuntos/farmacopeia/farmacopeia-brasileira
[10]
Brazil. Anvisa. RDC n°67, of October 8, 2007. Available from: https://bvsms.saude.gov.br/bvr/saudelegis/anvisa/2007/rdc0067_08_10_2007.html
[11]
dos Santos, N. V.; Moura, A. C.; Baptista, J. G. D.; Farache Filho, A. Brazil. Anvisa. RDC nº6Assessment of the quality of purified water used in pharmacies. 7, October 8,. J. Basic Applied Pharma. Sci., 2014.
[12]
Gonçalves, R.A.C.; Martinelli, H.K.; Castellani, A.M.; Gonçalves, J.E. Evaluation of quality control carried out in compounding and homeopathic pharmacies in Maringá, State of Paraná. Acta Scientiarum. Health Science, 2005, 27(2), 137-143.
[http://dx.doi.org/10.4025/actascihealthsci.v27i2.1378]
[13]
Ferraz, C. C.; Silva, M. L. Assessment of Quality Control in Pharmacies with Manipulation in the City of Sorocaba - SP. University Studies Magazine - REU, 2009, 34.
[14]
Yang, Z.; Zhou, Y.; Feng, Z.; Rui, X.; Zhang, T.; Zhang, Z. A review on reverse osmosis and nanofiltration membranes for water purification. Polymers, 2019, 11(8), 1252.
[http://dx.doi.org/10.3390/polym11081252] [PMID: 31362430]
[15]
Foster, J.E. Plasma-based water purification: Challenges and prospects for the future. Phys. Plasmas, 2017, 24(5), 055501.
[http://dx.doi.org/10.1063/1.4977921]
[16]
Frischkorn, H. Reverse osmosis: Chemical cleaning of desalination membranes in Ceará. REVTEC, 2016, 30(1), 61-76. [https://ojs.unifor.br/tec/article/view/5277
[17]
Mota, V.A.M.; Junior, J.A.O.; Chiari-Andréo, B.G. Control of Microbiological Contamination of Magistral Products. Revista Brasileira Multidisciplinar, 2017, 20(1), 33.
[http://dx.doi.org/10.25061/2527-2675/ReBraM/2017.v20i1.474]
[18]
Vieira, L. de J.; Valentini, A. Physicochemical Quality of Purified Water From Maipulation Pharmacies in the City of Campo Mourão; Revista Iniciare, 2017, p. 2.
[19]
World health organization. (WHO. Tech. Rep. Ser. (World Health Organ.), 2012, (970), 2012.
[20]
Lorenzo, C.; Raimundo, D.; Rocha, A.; Menão, M. Water purification methods for laboratories. Encicl. Biosf., 2018, 15(28), 1077-1092.
[http://dx.doi.org/10.18677/EnciBio_2018B88]
[21]
Nagy, E. Reverse osmosis. In: Basic Equations of Mass Transport Through a Membrane Layer; Elsevier, 2019; pp. 497-503.
[http://dx.doi.org/10.1016/B978-0-12-813722-2.00020-0]
[22]
Pahwa, R.; Piplani, M.; Sharma, P.; Nanda, A. Validation aspects of water treatment systems for pharmaceutical products. Trop. J. Pharm. Res., 2010, 9(1)
[http://dx.doi.org/10.4314/tjpr.v9i1.52042]
[23]
Pereira Filho, I.M.; Brunier, A.F. Quality management: Analysis of quality tools. In: Relação à Produtividade Do Segmento de Produtos Manipulados e Homeopáticos Da Farmácia de Manipulação Volta à Flora; Administra - Ação, 2013; p. 8.
[24]
Pontoriero, G. The quality of dialysis water. Nephrology Dialysis Transplantation, 2003, 18(90007)
[http://dx.doi.org/10.1093/ndt/gfg1074]
[25]
Quatrini, E.; Costantino, F.; Mba, D.; Li, X.; Gan, T.H. Monitoring a reverse osmosis process with kernel principal component analysis: A preliminary approach. Appl. Sci., 2021, 11(14), 6370.
[http://dx.doi.org/10.3390/app11146370]
[26]
Subramaniam, V.S.; Prakash, J.; Kamaruddin, S.; Khoo, S.W. A comprehensive validation framework addressing utility parameter validation for application in small and medium enterprises (SMEs):A case study in pharmaceutical industry. Cogent Eng., 2023, 10(1), 2166219.
[http://dx.doi.org/10.1080/23311916.2023.2166219]
[27]
Silva, G.S.; Tamaki, H.O.; Gonçalves, O.M. Implementation of Rational Water Use Programs on University Campuses. Ambient. Constr., 2006.
[28]
Silva, L.I.D.; Carneiro, M.C.; Emídio, V.S.; Henrique Junior, S.S.; Monteiro, M.I.C. Determination of nitrogen and total nitrogen forms in petroleum reservoir rocks by steam distillation and the indophenol method. Quim. Nova, 2006, 29(1), 46-51.
[http://dx.doi.org/10.1590/S0100-40422006000100010]
[29]
Zaidi, S.J.; Saleem, H. Designing of a reverse osmosis system.Reverse Osmosis Systems; Elsevier, 2022, pp. 209-239.
[http://dx.doi.org/10.1016/B978-0-12-823965-0.00012-2]

© 2024 Bentham Science Publishers | Privacy Policy