Generic placeholder image

Recent Advances in Electrical & Electronic Engineering

Editor-in-Chief

ISSN (Print): 2352-0965
ISSN (Online): 2352-0973

Research Article

Control Design for the NPC Three-Level Grid-Connected Converter with Non-Ideal Grid System

Author(s): Wenbao Hou*, Zang Ling and Delu Li

Volume 15, Issue 7, 2022

Published on: 09 September, 2022

Page: [533 - 543] Pages: 11

DOI: 10.2174/2352096515666220620100034

Price: $65

Abstract

Background: The large-scale distributed new energy integrations bring about various non-ideal grid situations, which could deteriorate the control performance of grid-connected converters.

Objective: This study aims to improve the control performance of the grid-connected converters when the grid is non-ideal.

Methods: Firstly, a neutral point clamped (NPC) three-level grid-connected converter was studied, and the characteristics of the non-ideal grid were analyzed in detail. Then, a real-time signal extraction method called generalized sliding discrete Fourier transform (GSDFT) has been proposed to extract the non-ideal signals, e.g., harmonic components and negative sequence components, based on which a double closed-loop control strategy was designed to improve the control performance of the grid-connected converters when the grid is non-ideal.

Results: The experimental results show that the converter double closed-loop control strategy in the non-ideal grid environment is suitable for a variety of non-ideal grid environments, and the gridconnected effect is good.

Conclusion: Firstly, this paper analyzes the characteristics of non-ideal grid and establishes the mathematical model of NPC three-level grid-connected converter in non-ideal grid environment. Secondly, aiming at the problem of characteristic harmonics and negative sequence components in non-ideal power grid, a real-time and fast extraction method of non-ideal signals based on generalized sliding discrete Fourier transform is proposed. Finally, taking the three-phase grid current of grid-connected converter as the control target, the closed-loop control strategy of non-ideal signal extraction based on GSDFT is designed, and a good control effect is achieved.

Keywords: Non-ideal grid system, grid-connected converter, generalized sliding discrete Fourier transform, double control, grid voltage, neutral point clamped.

Graphical Abstract

[1]
S.X. Chen, H.B. Gooi, and M.Q. Wang, "Sizing of energy storage for microgrids", IEEE Trans. Smart Grid, vol. 3, no. 1, pp. 142-151, 2012.
[http://dx.doi.org/10.1109/TSG.2011.2160745]
[2]
J. Yu, X. Lin, D. Song, R. Yu, Y. Li, and M. Su, "Harmonic instability and amplification for grid-connected inverter with voltage harmonics compensation considering phase-locked loop", IEEE J. Emerg. Sel. Top. Power Electron., vol. 8, no. 4, pp. 3944-3959, 2020.
[http://dx.doi.org/10.1109/JESTPE.2019.2936257]
[3]
D. Wang, C. Liu, and G. Li, "Optimal control strategy for PMSG wind power system to restrain the oscillation of DC voltage and transmission power under asymmetrical grid fault", In International Conference on Renewable Power Generation (RPG 2015), Beijing, 2015, pp. 1-5
[http://dx.doi.org/10.1049/cp.2015.0480]
[4]
Z. Zhihua, B. Xuejun, W. Huanning, H. Yan, T. Hengyu, and Y. Hejun, "Research on harmonic traceability method of reference meter based on power comparison", In 2021 5th International Conference on Smart Grid and Smart Cities (ICSGSC), 18-20 June, 2021.
Tokyo, Japan, 2021, pp. 23-27. [http://dx.doi.org/10.1109/ICSGSC52434.2021.9490427]
[5]
J. Zhou, F. Tang, Z. Xin, S. Huang, and P.C. Loh, "Active power decoupling methods for three-phase grid-connected converters under unbalanced grid conditions", In 2017 IEEE 18th Workshop on Control and Modeling for Power Electronics (COMPEL), 9-12 July, 2017.
Stanford, CA, USA, 2017, pp. 1-7. [http://dx.doi.org/10.1109/COMPEL.2017.8013303]
[6]
A. Akhavan, H.R. Mohammadi, J.C. Vasquez, and J.M. Guerrero, "Passivity-Based design of plug-and-play current-controlled grid-connected inverters", IEEE Trans. Power Electron., vol. 35, no. 2, pp. 2135-2150, 2020.
[http://dx.doi.org/10.1109/TPEL.2019.2920843]
[7]
V.R. Chowdhury, and J.W. Kimball, "Control of a three-phase grid-connected inverter under non-ideal grid conditions with online parameter update", IEEE Trans. Energ. Convers., vol. 34, no. 3, pp. 1613-1622, 2019.
[http://dx.doi.org/10.1109/TEC.2019.2898152]
[8]
N.S. Pande, S.P. Gawande, and M.R. Ramteke, "Control of D-STATCOM under unbalanced and distorted voltages using synchronous detection method for load compensation", International Conference on Recent Advances and Innovations in Engineering (ICRAIE-2014), 9-11 May, 2014.
Jaipur, India, 2014, pp. 1-6. [http://dx.doi.org/10.1109/ICRAIE.2014.6909302]
[9]
L. Bao, J. Xia, Z. Dong, Y. Deng, Y. Lu, and Y. Yang, "An improved three-phase four-wire harmonic detection algorithm based on multi-synchronous rotating frame transformation", In IECON 2019-45th Annual Conference of the IEEE Industrial Electronics Society.
vol. 1, pp. 2115-2120, 2019. [http://dx.doi.org/10.1109/IECON.2019.8927561]
[10]
M.A. Shuvra, and B.H. Chowdhury, "Selective harmonic compensation by smart inverters using Multiple-Complex-Coefficient-Filter (MCCF) during unbalanced fault condition", In 2017 IEEE North American Power Symposium (NAPS), 17-19 Sept, 2017.
Morgantown, WV, USA, 2017, pp. 1-6. [http://dx.doi.org/10.1109/NAPS.2017.8107384]
[11]
Y. Li, P. Zhang, L. Zhang, and B. Wang, "Active synchronous detection of deception attacks in microgrid control systems", IEEE Trans. Smart Grid, vol. 8, no. 1, pp. 373-375, 2017.
[http://dx.doi.org/10.1109/TSG.2016.2614884]
[12]
Z. Liu, B. Zhang, K. Zhou, and J. Wang, "Virtual variable sampling discrete fourier transform based selective odd-order harmonic repetitive control of DC/AC converters", IEEE Trans. Power Electron., vol. 33, no. 7, pp. 6444-6452, 2018.
[http://dx.doi.org/10.1109/TPEL.2017.2764020]
[13]
H. Wen, J. Zhang, Z. Meng, S. Guo, F. Li, and Y. Yang, "Harmonic estimation using symmetrical interpolation FFT based on triangular self-convolution window", IEEE Trans. Industr. Inform., vol. 11, no. 1, pp. 16-26, 2015.
[http://dx.doi.org/10.1109/TII.2014.2362491]
[14]
J. Talla, and V. Blahnik, "Sliding DFT based grid to ground admittance estimation with guaranteed numerical stability", In IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society.
pp. 4344-4349, 2017. [http://dx.doi.org/10.1109/IECON.2017.8216747]
[15]
M. Xie, H. Wen, C. Zhu, and Y. Yang, "DC offset rejection improvement in single-phase SOGI-PLL algorithms: Methods review and experimental evaluation", IEEE Access, vol. 5, pp. 12810-12819, 2017.
[http://dx.doi.org/10.1109/ACCESS.2017.2719721]
[16]
S. Golestan, J.M. Guerrero, and J.C. Vasquez, "Hybrid adaptive/nonadaptive delayed signal cancellation-based phase-locked loop", IEEE Trans. Ind. Electron., vol. 64, no. 1, pp. 470-479, 2017.
[http://dx.doi.org/10.1109/TIE.2016.2596713]
[17]
C. Gao, Q. Chen, L. Zhang, and S. Quan, "Current multi-loop control strategy for grid-connected inverter with LCL filter", In 2018 33rd Youth Academic Annual Conference of Chinese Association of Automation (YAC), 18-20 May, 2018.
Nanjing, China, 2018, pp. 712-7716. [http://dx.doi.org/10.1109/YAC.2018.8406464]
[18]
S.J. Pinto, G. Panda, and R. Peesapati, "An implementation of hybrid control strategy for distributed generation system interface using xilinx system generator", IEEE Trans. Industr. Inform., vol. 13, no. 5, pp. 2735-2745, 2017.
[http://dx.doi.org/10.1109/TII.2017.2723434]
[19]
C.S. Lim, H.H. Goh, and S.S. Lee, "Long-prediction-horizon near-optimal model predictive grid current control for PWM-Driven VSIs with LCL filters", IEEE Trans. Power Electron., vol. 36, no. 2, pp. 2246-2257, 2021.
[http://dx.doi.org/10.1109/TPEL.2020.3011227]
[20]
Z. Zhang, X. Liu, Y. Zhang, C. Zhang, and W. Deng, "A novel current control method based on dual-mode structure repetitive control for three-phase power electronic load", IEEE Access, vol. 9, pp. 144406-144416, 2021.
[http://dx.doi.org/10.1109/ACCESS.2021.3122123]

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy