Generic placeholder image

Current Pharmaceutical Analysis

Editor-in-Chief

ISSN (Print): 1573-4129
ISSN (Online): 1875-676X

Research Article

Differential Pulse Voltammetric Determination of Piroxicam on Lanthanide Ferric Oxide Nanoparticles-Carbon Paste Modified Electrode

Author(s): Isaac Yves Lopes de Macedo, Morgana Fernandes Alecrim, Luane Ferreira Garcia, Aparecido Ribeiro de Souza, Wallans Torres Pio dos Santos, Eric de Souza Gil*, Laura M. Cubillana-Aguilera and Jose Maria Palacios-Santander*

Volume 14, Issue 3, 2018

Page: [271 - 276] Pages: 6

DOI: 10.2174/1573412913666170410131223

Price: $65

Abstract

Introduction: Piroxicam (PRX) is a widely consumed anti-inflammatory drug, and the assays of its tablets and gels for quality control are mostly performed through High Performance Liquid Chromatography with Ultraviolet Detector (HPLC-UV).

Methods: In this regard, an alternate approach, LaFeO3 nanoparticles-modified carbon paste electrode was prepared in order to carry out PRX analysis by using voltammetric approaches.

Results: The modified electrode showed better analytical signal. The calibration curve is in the concentration range of 9.00 and 180.00 µmol·L-1 and the limit of detection was obtained as 1.00 µmol·L1 for PRX. The calculated recovery rate was fairly good (99.14%) in comparison with the declared value in the commercial product.

Conclusion: As shown by the low overall process cost, performance quickness and analytical results, the proposed method of electroanalysis with the LaFeO3 nanoparticles-modified carbon paste electrode presents a viable and interesting alternative approach to identification and determination of PRX compound in commercial products.

Keywords: LaFeO3, nanoparticles, modified carbon paste electrode, electroanalysis, voltammetry, piroxicam, oxidation.

Graphical Abstract


Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy