Generic placeholder image

Current Bioactive Compounds

Editor-in-Chief

ISSN (Print): 1573-4072
ISSN (Online): 1875-6646

Research Article

Determination of Alendronate Sodium in Tablets by Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy

Author(s): Sawsan Ibrahim, Shaik I. Khalivulla and Gabriel A. Akowuah

Volume 13, Issue 1, 2017

Page: [71 - 77] Pages: 7

DOI: 10.2174/1573407212999160506112738

Price: $65

Abstract

Background: Alendronate sodium (the sodium salt of 4-Amino-1-hydroxy-1-bisphosphonic acid) is a potent anti-resorptive drug that is widely used for the treatment of osteoporosis and Paget’s disease. Its analysis is challenging due to the lack of chromophore in its chemical structure. This study describes a quick and simple attenuated total reflectance (ATR) Fourier transform infrared (FTIR) spectroscopic method for the determination of alendronate in tablets.

Method: Nicolet™ iS5 FTIR spectrometer equipped with iD5 ATR accessory featuring a top plate diamond crystal with a fixed angel of incidence of 42° and controlled by OMNIC software was used for spectra collection. TQ Analyst software was used for data processing. The calibration model was based on Beer’s Law using the peak at 1543.83 cm-1 corresponding to the phosphate group of alendronate.

Results: The method was found to be linear in the range of 0.5-5% w/w with excellent correlation coefficient of 0.9999. The method was validated according to the International Conference on Harmonization (ICH) guidelines. Limit of detection and limit of quantification values were 0.05% w/w and 0.14% w/w, respectively. The relative standard deviations for intraday precision and interday precision for five replicate measurements were 2.32% and 2.58%, respectively. Mean percentage recovery was found to be 99.73±1.33%. The validated method was used for the quantification of alendronate in tablets and percentage of labelled amount was found to be 101.11±1.9%.

Conclusion: The ATR accessory gave the advantage of very simple sample preparation that and less analysis time. The phosphate peak at 1543.83 cm-1 in the IR spectrum was specific for alendronate. Tablet excipients showed no interference with the analysis. The validated ATR-FTIR method was found to be suitable for routine analysis of alendronate in tablet.

Keywords: Alendronate sodium, attenuated total reflectance, bisphosphonates, Fourier transform infrared spectroscopy, tablets.

Graphical Abstract


Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy