Analytical Solutions to Bloch NMR Flow Equation in Porous System: Future and Emerging Magnetic Resonance Computational Imaging for Medical and Biomedical Engineering

Author(s): Michael O. Dada and Bamidele O. Awojoyogbe

Volume 5, Issue 1, 2015

Page: [31 - 43] Pages: 13

DOI: 10.2174/2451827105666151103005323

Price: $65

Abstract

Background: In most brain tissue architecture, water diffusion is anisotropic or directional and can be treated as a restricted geometry. This requires the specification of diffusion coefficients as function of space coordinate(s) and such a phenomenon is an indication of non-uniform compartmental conditions observed in porous media. Since the diffusion coefficient becomes directional, the imaging process becomes very complex and the analytical solutions to the NMR diffusion tensor equation with variable coefficients for non-uniform tissue composition can open a new field of research in diffusion tensor imaging.

Metohod: Detailed analytical solutions to the Bloch NMR flow differential equation in cylindrical and spherical restricted geometries needed in the study of general motion of pathological tissues are presented. The system considered was treated as a rigid body which is fundamental to the formulation of the concept of stress in a viscous fluid (blood flow). We show how the analytical solutions to the Bloch NMR flow equation can provide fundamental computational tools that can stimulate interest for future research at the molecular and atomic scales for conceptualization, characterization and development of emerging magnetic resonance imaging theory and applications.

Results and Conclusion: Diffusion tensor imaging is treated theoretically by the analytical solutions to fundamental Bloch NMR equations for Magnetic Resonance Imaging. We derived a differential equation for diffusion in both cylindrical and spherical geometries. The general strategy is to consider the diffusion equation together with a forcing function, which is due to the time dependent magnetic field. First the diffusion equation is considered in terms of the instantaneous change to obtain the spatial and time dependence of magnetization. Then the time dependent magnetization is integrated over time to obtain the steady state solutions for the diffusion tensor equation derived from the Bloch NMR flow equations. It is very interesting to note that the derived experimental parameters are very much related to magnetic resonance imaging parameters where the distribution and nature of axonal injuries can be quantified in terms of refined measurements of tortuosity, permeability, porosity and formation factor.

Keywords: Apparent diffusion coefficient, cylindrical and spherical geometries, diffusion tensor, diffusion NMR equation, permeability, porosity, tortuosity.