Generic placeholder image

Current Pharmaceutical Analysis

Editor-in-Chief

ISSN (Print): 1573-4129
ISSN (Online): 1875-676X

Voltammetric Stripping Methods for Direct Determination of Disopyramide

Author(s): Muharrem Duran, Zehra Durmus, Ibrahim H. Tasdemir and Esma Kilic

Volume 8, Issue 1, 2012

Page: [28 - 36] Pages: 9

DOI: 10.2174/157341212798995584

Price: $65

Abstract

Electrochemical behavior of disopyramide (DPA) on glassy carbon electrode (GCE) was investigated by using cyclic voltammetry, square-wave voltammetry and constant potential bulk electrolysis. Adsorption and diffusion properties of DPA were evaluated. Differential pulse anodic adsorptive stripping voltammetric (DPAAdSV) and squarewave anodic adsorptive stripping voltammetric (SWAAdSV) methods were developed for its direct determination in pharmaceutical preparations and biological samples. Linear working concentration range for both methods was found as 3x10-7 M (0.102 mg/L) - 3x10-6 M (1.0 mg/L). Limit of detection and limit of quantitation for DPAAdSV were found to be 2.9x10-7 M (0.10 mg/L) and 9.5x10-7 M (0.32 mg/L), respectively and they were calculated to be 1.4x10-7 M (0.05 mg/L) and 4.5x10-7 M (0.15 mg/L) for SWAAdSV. Proposed methods were successfully applied to determine the content of DPA in pharmaceutical preparations and biological samples.

Keywords: Disopyramide, Electrochemical behavior, Voltammetric stripping methods, Assay, Glassy carbon electrode, Limit of detection, Limit of quantitation, Pharmaceutical preparations, Biological samples, Validation parameters


Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy