Generic placeholder image

Current Analytical Chemistry

Editor-in-Chief

ISSN (Print): 1573-4110
ISSN (Online): 1875-6727

Short Communication

A Novel Electrochemical Genosensor for Specific Detection of xanQ Gene in Escherichia coli Strains in Water

Author(s): Rehan Deshmukh, Utpal Roy* and Sunil Bhand

Volume 18, Issue 7, 2022

Published on: 30 March, 2022

Page: [852 - 855] Pages: 4

DOI: 10.2174/1573411018666220126094751

Price: $65

conference banner
Abstract

Background: A rapid and specific detection of pathogens is of great importance from public health viewpoint as well as from economic perspectives. Genosensor based on sequence specific detection of Escherichia coli facilitates significant improvements in rapidity and specificity over traditional microbiological methods.

Objective: The present study was aimed at identifying a sequence of xanQ genetic markers for designing the DNA sensing probe and fabricating a genosensor using the interdigitated gold electrode (IDE).

Methods: A label-free genosensor for E. coli detection in water by a novel nucleic acid sensing probe, URecA1016 is reported. The URecA1016 sensing probe-functionalized gold-interdigitated electrode surface by covalent coupling using 11-Mercaptoundecanoic acid (crosslinker) to develop the electrochemical genosensor.

Results: Upon DNA hybridization, the non-Faradaic sensing measurements showed a decreasing capacitance value with 10 min response time at 120 Hz frequency and 10 mV applied potential. The linearity range of the genosensor was between 1 and 1000 pg/mL for DNA of E. coli with a limit of quantification (LoQ) of 1.27 pg DNA/mL of E. coli (equivalent to approximately 150 CFU/mL) at 95% confidence. Whilst the genosensor was E. coli species-specific as has been tested for the detection of E. coli MTCC 3221, E. coli O157:H7 ATCC 43895, E. coli O78:H11 MTCC 723 any cross-reactivity could not be observed with DNA of Shigella flexneri MTCC 9543 and Bacillus subtilis MTCC 736. The capacitance change responses were also recorded and discussed.

Conclusion: The URecA1016 sensing probe was found to be specific for the detection of different E. coli species spiked in water. The results obtained in our study demonstrated the possible application potential of genosensor for E. coli detection in real water samples.

Keywords: E. coli, impedance, URecA1016, hybridization, non-Faradaic, electrochemical genosensor.

« Previous
Graphical Abstract

[1]
Deshmukh, R.A.; Joshi, K.; Bhand, S.; Roy, U. Recent developments in detection and enumeration of waterborne bacteria: A retrospective minireview. MicrobiologyOpen, 2016, 5(6), 901-922.
[http://dx.doi.org/10.1002/mbo3.383] [PMID: 27397728]
[2]
Lupindu, A.M. Epidemiology of Shiga Toxin- producing Escherichia coli O157:H7 in Africa in review. S. Afr. J. Infect. Dis., 2018, 33(1), 24-30.
[http://dx.doi.org/10.1080/23120053.2017.1376558]
[3]
Saxena, T.; Kaushik, P.; Krishna Mohan, M. Prevalence of E. coli O157:H7 in water sources: An overview on associated diseases, out-breaks and detection methods. Diagn. Microbiol. Infect. Dis., 2015, 82(3), 249-264.
[4]
Hussein, H.S. Prevalence and pathogenicity of Shiga toxin-producing Escherichia coli in beef cattle and their products. J. Anim. Sci., 2007, 85(13)(Suppl.), E63-E72.
[http://dx.doi.org/10.2527/jas.2006-421] [PMID: 17060419]
[5]
Chekabab, S.M.; Paquin-Veillette, J.; Dozois, C.M.; Harel, J. The ecological habitat and transmission of Escherichia coli O157:H7. FEMS Microbiol. Lett., 2013, 341(1), 1-12.
[http://dx.doi.org/10.1111/1574-6968.12078] [PMID: 23305397]
[6]
Li, B.; Chen, J.Q. Real-time PCR methodology for selective detection of viable Escherichia coli O157:H7 cells by targeting Z3276 as a genetic marker. Appl. Environ. Microbiol., 2012, 78(15), 5297-5304.
[http://dx.doi.org/10.1128/AEM.00794-12] [PMID: 22635992]
[7]
Karatza, P.; Frillingos, S. Cloning and functional characterization of two bacterial members of the NAT/NCS2 family in Escherichia coli. Mol. Membr. Biol., 2005, 22(3), 251-261.
[http://dx.doi.org/10.1080/09687860500092927] [PMID: 16096267]
[8]
Deshmukh, R.A.; Bhand, S.; Roy, U. A novel molecular quantitative method for rapid and sensitive detection of Escherichia coli from roof- harvested rainwater. Anal. Methods, 2019, 11(25), 3155-3167.
[http://dx.doi.org/10.1039/C9AY00587K]
[9]
Deshmukh, R.; Prusty, A.K.; Roy, U.; Bhand, S. A capacitive DNA sensor for sensitive detection of Escherichia coli O157:H7 in potable water based on the z3276 genetic marker: fabrication and analytical performance. Analyst (Lond.), 2020, 145(6), 2267-2278.
[http://dx.doi.org/10.1039/C9AN02291K] [PMID: 31996887]
[10]
Bacher, G.; Pal, S.; Kanungo, L.; Bhand, S.A. Label- free silver wire based impedimetric immunosensor for detection of Aflatoxin M1 in milk. Sens. Actuators B Chem., 2012, 168, 223-230.
[http://dx.doi.org/10.1016/j.snb.2012.04.012]
[11]
Ahmad, A.; Moore, E. Electrochemical immunosensor modified with self-assembled monolayer of 11-mercaptoundecanoic acid on gold electrodes for detection of benzo[a]pyrene in water. Analyst (Lond.), 2012, 137(24), 5839-5844.
[http://dx.doi.org/10.1039/c2an35236b] [PMID: 23099427]
[12]
Berggren, C.; Bjarnason, B.; Johansson, G. Capacitive biosensors. Electroanalysis, 2001, 13(3), 173-180.
[http://dx.doi.org/10.1002/1521-4109(200103)13:3<173:AID-ELAN173>3.0.CO;2-B]
[13]
Ruan, C.; Yang, L.; Li, Y. Immunobiosensor chips for detection of Escherichia coil O157:H7 using electrochemical impedance spectros-copy. Anal. Chem., 2002, 74(18), 4814-4820.
[http://dx.doi.org/10.1021/ac025647b] [PMID: 12349988]
[14]
Yang, L.; Li, Y.; Erf, G.F. Interdigitated Array microelectrode-based electrochemical impedance immunosensor for detection of Escherich-ia coli O157:H7. Anal. Chem., 2004, 76(4), 1107-1113.
[http://dx.doi.org/10.1021/ac0352575] [PMID: 14961745]

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy