Abstract
Lipophilic macrocyclic hexaamines supported by a poly(vinyl chloride) PVC matrix were used for the construction of liquid membrane electrodes sensitive toward adenine nucleotide polyanions. The membrane potential strongly depended on the pH of the sample solution. This phenomenon occurs due to the ability of the ionophore to accept protons. Therefore, the optimum pH was determined based on potential-pH profile. The potential measurements were carried out at pH 6.0 in the presence of 10-2 M 2- [N-morpholino] ethanesulfonic acid (MES) buffer. The potential response of these electrodes toward ATP- 4 and/or HATP-3 was close to the Nernstian slope. The selectivities against ADP-3, AMP-2, HPO4 -2 , and monovalent inorganic anions were estimated using the matched potential method. Chloride ions slightly affected potential response of the electrodes toward ATP-4/HATP-3. The influence of ionophore chemical structure on the selectivity and the sensitivity of these electrodes is briefly discussed.
Combinatorial Chemistry & High Throughput Screening
Title: Polymeric Liquid Membrane Electrodes Incorporated with Macrocyclic Hexaamines for Screening Adenine Nucleotides
Volume: 3 Issue: 6
Author(s): Iwona Szymanska, Hanna Radecka, Jerzy Radecki, Marek Pietraszkiewicz and Oksana Pietraszkiewicz
Affiliation:
Abstract: Lipophilic macrocyclic hexaamines supported by a poly(vinyl chloride) PVC matrix were used for the construction of liquid membrane electrodes sensitive toward adenine nucleotide polyanions. The membrane potential strongly depended on the pH of the sample solution. This phenomenon occurs due to the ability of the ionophore to accept protons. Therefore, the optimum pH was determined based on potential-pH profile. The potential measurements were carried out at pH 6.0 in the presence of 10-2 M 2- [N-morpholino] ethanesulfonic acid (MES) buffer. The potential response of these electrodes toward ATP- 4 and/or HATP-3 was close to the Nernstian slope. The selectivities against ADP-3, AMP-2, HPO4 -2 , and monovalent inorganic anions were estimated using the matched potential method. Chloride ions slightly affected potential response of the electrodes toward ATP-4/HATP-3. The influence of ionophore chemical structure on the selectivity and the sensitivity of these electrodes is briefly discussed.
Export Options
About this article
Cite this article as:
Szymanska Iwona, Radecka Hanna, Radecki Jerzy, Pietraszkiewicz Marek and Pietraszkiewicz Oksana, Polymeric Liquid Membrane Electrodes Incorporated with Macrocyclic Hexaamines for Screening Adenine Nucleotides, Combinatorial Chemistry & High Throughput Screening 2000; 3 (6) . https://dx.doi.org/10.2174/1386207003331436
DOI https://dx.doi.org/10.2174/1386207003331436 |
Print ISSN 1386-2073 |
Publisher Name Bentham Science Publisher |
Online ISSN 1875-5402 |

- Author Guidelines
- Bentham Author Support Services (BASS)
- Graphical Abstracts
- Fabricating and Stating False Information
- Research Misconduct
- Post Publication Discussions and Corrections
- Publishing Ethics and Rectitude
- Increase Visibility of Your Article
- Archiving Policies
- Peer Review Workflow
- Order Your Article Before Print
- Promote Your Article
- Manuscript Transfer Facility
- Editorial Policies
- Allegations from Whistleblowers